BP45F0044
Wireless Charger Flash MCU
2. The row below the 5V trim voltage row is provided to show the values for the full VDD range operating
voltage. It is recommended that the trim voltage is fixed at 5V for application voltage ranges from 3.3V to 5.5V.
Low Speed Internal Oscillator – LIRC – Frequency Accuracy
Test Conditions
Symbol
Parameter
Min.
Typ.
Max.
Unit
VDD
Temp.
5V
25°C
25°C
25.6
12.8
8
32
32
32
—
38.4
41.6
60
fLIRC
LIRC Frequency
kHz
3.3V~5.5V
—
-40°C~85°C
25°C
tSTART
LIRC Start Up Time
—
100
μs
Operating Frequency Characteristic Curves
System Operating Frequency
16MHz
~
~
3.3V
5.5V
Operating Voltage
System Start Up Time Characteristics
Ta=-40°C~85°C
Min. Typ. Max. Unit
Test Conditions
Symbol
Parameter
System Start-up Time
VDD
—
Conditions
fSYS=fH~fH/64, fH=fHIRC
fSYS=fSUB=fLIRC
—
—
—
—
16
2
—
—
—
—
tSYS
tSYS
tSYS
tSYS
Wake-up from Condition where fSYS is off
—
—
fSYS=fH~fH/64, fH=fHIRC
fSYS=fSUB=fLIRC
2
System Start-up Time
Wake-up from Condition where fSYS is on
tSST
—
2
System Speed Switch Time
FAST to SLOW Mode or SLOW to FAST Mode
fHIRC switches from off
to on
—
—
—
—
16
50
—
tHIRC
System Reset Delay Time
Reset Source from Power-on Reset or LVR
Hardware Reset
RRPOR=5V/ms
—
25
150
ms
System Reset Delay Time
Reset Source from WDTC/LVRC Software Reset
tRSTD
System Reset Delay Time
Reset Source from WDT Overflow
—
—
—
—
8.3 16.7 50.0 ms
45 90 375 μs
tSRESET
Minimum Software Reset Width to Reset
Note: 1. For the System Start-up time values, whether fSYS is on or off depends upon the mode type and the chosen
fSYS system oscillator. Details are provided in the System Operating Modes section.
2. The time units, shown by the symbols, tHIRC, etc., are the inverse of the corresponding frequency values as
provided in the frequency tables. For example tHIRC=1/fHIRC, tSYS=1/fSYS, etc.
3. If the LIRC is used as the system clock and if it is off when in the SLEEP Mode, then an additional LIRC start
up time, tSTART, as provided in the LIRC frequency table, must be added to the tSST time in the table above.
4. The System Speed Switch Time is effectively the time taken for the newly activated oscillator to start up.
Rev. 1.00
10
March 17, 2020