Printed Circuit Board Fuses
PC-Tron Series
Description
• RoHS Compliant (-R)
• Non-Time Delay
• Ideal for high voltage DC applications
• Board washable
• Optional mounting socket available (PCS)
• Available in different lead configurations
Agency Information
• UL Recognized - File E19180, Guide JDYX2
• CSA Certified - File 42731, Class 1422-01
mm
Dimensions
⁄(inches)
AC TIME-CURRENT CHARACTERISTICS
.005"
.13 mm
Dimensional Data: All tolerances
% of Amp Rating
100%
Opening Time
4 hours minimum
10 second maximum
Mounting Socket
200%
• Available as option. (Specify catalog number BK/PCS
(100-in) and short fuse lead length — PCC or PCE)
Ordering
• Specify packaging code and product code
(i.e., BK/PCB-1/2)
Socket (PCS)
.030"
DC Application
(2.41mm)
.300"
The PC-Tron subminiature fuse is UL Recognized for
DC supplementary overcurrent protection to provide
individual protection for components or internal circuits in
equipment. Suitability for a specific application is
dependent on time constants and capacitance values. It
is the responsibility of the customer to evaluate the
information provided for applicability to their particular
application.
(7.62mm)
.095"
.200"
(2.41mm)
(5.08mm)
.290"
(7.37mm)
.12" .010"
(3.05mm 0.25mm)
SPECIFICATIONS
Product Code / Amp Rating
(Use -R for RoHS compliant version)
PCB - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
Lead
Length
Voltage
AC
Voltage
Rating DC
450V
DC Interrupting
Rating AC Interrupting
Min.
Max.
Full - 0.750" (straight)
250V
50A @ 250V
10kA @ 125V
50A @ 250V
50A @ 250V
10kA @ 125V
50A @ 250V
10kA @ 125V
10kA @ 125V
10kA @ 125V
50A @ 250V
10kA @ 125V
50A @ 250V
10kA @ 125V
10kA @ 125V
50A @ 250V
10kA @ 125V
50A @ 250V
10kA @ 125V
10kA @ 125V
300
5900A
PCB - 3
Full - 0.750" (straight)
Short 0.100" (straight)
250V
250V
350V
450V
300
300
4400A
5900A
PCC - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCC - 3
Short 0.100" (straight)
250V
350V
300
4400A
PCD - 5
PCE - 5
PCF - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
Full - 0.750" (straight)
Short 0.100" (straight)
0.475"
125V
125V
250V
250V
250V
450V
300
300
300
4200A
4200A
5900A
PCF - 3
0.475"
250V
350V
300
4400A
PCG - 5
PCH - 1/2, 3/4, 1, 1-1/2, 2, 2-1/2
0.475"
0.125"
125V
250V
250V
450V
300
300
4200A
5900A
PCH - 3
PCI - 5
0.125"
0.125"
250V
125V
350V
250V
300
300
4400A
4200A
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.