Assembly instructions for plugs and sockets (with optional mold stop)
1
FG●
PH●
1
PB●
1. Cable preparation
0.5
Series
L
S
9
T
L
Strip the cable according to dimen-
sions of the table, then widen the
shield.
0.2
T
14
3.0
MM
20 15 3.5
0M to 5M
0.5
S
Note: dimensions are in mm.
2. Cable termination
2.1 With shielded cables, widen and pull the shield all the way to the back.
Fix the appropriate positioner onto the crimping tool and set the selec-
tor to the number corresponding to the AWG of the conductor used as
indicated on the positioner label.
Crimp
1
1
Fit the conductor into the contact ➀; make sure it is visible through the
contact’s inspection hole.
Crimp
Slide the conductor-contact assembly into the open crimping tool;
make sure that the contact is pushed fully into the positioner. Close the
tool. Remove from crimping tool and check that conductor is secure in
contact and shows in inspection hole.
2.2 Arrange the conductor-contact assemblies according to the markings,
into the rear cable seal.
Push them deeply into the insulator, using tweezers if necessary;
check that all the contacts are correctly located in the insulator:
1) by verifying the alignment of the contacts at the front of the insu-
lator and 2) by gently pulling on each conductor.
Verification should also be made using the appropriate retention tes-
ting tool.
2.3 Bring the shield around the rear of connector until the mold stop.
Secure it with a band-it tie-wrap (not furnished) to fix the shield in place.
Cut off the possible shield surplus.
Steel tie-wrap band (~3 mm wide)
Steel tie-wrap band (~3 mm wide)
2.4 Custom overmold cable assembly.
Overmolding
Overmolding
40