BD83A44EFV-M BD83A44MUF-M
Pin Descriptions – continued
Pin No.
Signal Type
Pin Name
Function
(Note 1)
EFV MUF
Switching pulse number setting: Pulse addition function is provided to stabilize DC/DC
converter output voltage even when PWM Duty is low. The number of switching pulses to be
added can be set by the capacitance value connected between the PLSET pin and the GND
pin.
17 14 PLSET
A
18 15
20 16
19 17
PGND
SW
P
P
-
Large current ground 2: GND of DC/DC converter. Use it for COUT ground.
FET drain signal for boost: Switching signal output of DC/DC converter. Connect the SW
pin to the node between the inductor and the rectifier diode.
N.C.
Not connected internally.
Output for driving the load switch gate: The signal output for driving the gate of the load
switch. When the input overcurrent protection is activated, the load switch is turned OFF as
LDSW pin voltage = VCC pin voltage.
22 18
23 19
LDSW
CSH
P
A
Input current detection input: The input current is converted to voltage by the input current
detection resistor (RCSH) connected between the VCC-CSH pin and detected by the CSH
pin. Turns the load switch OFF when the input overcurrent protection is activated.
Power supply voltage input: The input operating voltage range is 4.5 V to 48.0 V, but when
the IC is started, start it with VCC ≥ 5.5 V. The decoupling capacitor (CVCC) between the
VCC pin and the GND pin should be as close to the IC pin as possible.
24 20
21 21
VCC
N.C.
REG
P
-
Not connected internally.
Internal reference voltage: Used as the reference voltage for the internal circuit. 5 V is
generated and output by setting the EN pin to High. Connect a capacitance of 2.2 μF for
phase compensation.
1
22
A
Small signal ground: Use this for the ground of external components connected to the
REG, RT, COMP, ADIM, ISET, PLSET, OVP, and VCC pins.
2
3
23
24
GND
EN
A
Enable input: The EN pin is turned High to activate the internal circuit. The internal circuit
stops and the standby state is set by setting to Low.
I
EXP-
PAD
-
-
The EXP-PAD should be connected to the board ground.
(Note 1) A: Sensitive signal such as detect and reference, I: Input signal from other units, O: Output signal to other units, P: Large current signal susceptible to
impedance, including transient current.
www.rohm.com
TSZ02201-0T2T0B200460-1-2
© 2022 ROHM Co., Ltd. All rights reserved.
4/47
TSZ22111 • 15 • 001
08.May.2023 Rev.001