BCR12PM-14LJ
Preliminary
Maximum Transient Thermal Impedance
Characteristics (Junction to ambient)
Maximum On-State Power Dissipation
16
103
102
No Fins
14
12
10
8
360° Conduction
Resistive,
inductive loads
101
6
100
4
2
10−1
0
101
102
103
104
105
0
2
4
6
8
10 12 14 16
Conduction Time (Cycles at 60Hz)
RMS On-State Current (A)
Allowable Case Temperature vs.
RMS On-State Current
Allowable Ambient Temperature vs.
RMS On-State Current
160
140
120
100
80
160
140
120
100
80
Curves apply regardless
of conduction angle
All fins are black painted
aluminum and greased
Curves apply regardless of
conduction angle
Resistive, inductive loads
Natural convection
60
60
120 120 t2.3
100 100 t2.3
40
40
360° Conduction
20
20 Resistive,
60 × 60 × t2.3
inductive loads
0
0
0
2
4
6
8
10 12 14 16
0
2
4
6
8
10 12 14 16
RMS On-State Current (A)
RMS On-State Current (A)
Allowable Ambient Temperature vs.
RMS On-State Current
Repetitive Peak Off-State Current vs.
Junction Temperature
105
160
140
120
100
80
Natural convection
No Fins
Curves apply regardless
of conduction angle
Resistive, inductive loads
Typical Example
104
103
102
60
40
20
0
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
RMS On-State Current (A)
–40
0
40
80
120
160
Junction Temperature (°C)
R07DS0910EJ0100 Rev.1.00
Nov 14, 2012
Page 4 of 7