BCM® in a VIA Package
Bus Converter
BCM4414xG0F4440yzz
S
®
C
NRTL US
C
US
Isolated Fixed-Ratio DC-DC Converter
Features & Benefits
Product Ratings
• Up to 40A continuous low voltage side current
• Fixed transformation ratio (K) of 1/16
• Up to 776W/in3 power density
• 97.5% peak efficiency
VHI = 544V (400 – 700V)
ILO = up to 40A
K = 1/16
VLO = 34V (25 – 43.8V)
(no load)
Product Description
• Integrated filtering
The BCM4414xG0F4440yzz in a VIA package is a high efficiency
Bus Converter, operating from a 400 to 700VDC high voltage bus
to deliver an isolated 25 to 43.8VDC unregulated, low voltage.
• Parallel operation for multi-kW arrays
• OV, OC, UV, short circuit and thermal protection
• 4414 package
This unique ultra-low profile module incorporates DC-DC
conversion, integrated filtering and PMBus™ commands and
controls in a chassis or PCB mount form factor.
• High MTBF
• Thermally enhanced VIA package
• PMBus™ management interface
• Bidirectional operation (start up in forward direction only)
The BCM offers low noise, fast transient response and industry
leading efficiency and power density. A low voltage side
referenced PMBus compatible telemetry and control interface
provides access to the BCM’s configuration, fault monitoring, and
other telemetry functions.
Typical Applications
Leveraging the thermal and density benefits of Vicor’s VIA
packaging technology, the BCM module offers flexible thermal
management options with very low top and bottom side
thermal impedances.
• High Voltage DC Power Distribution
• 3 Phase AC-DC Converters
• Information and Communication
Technology (ICT) Equipment
When combined with downstream Vicor DC-DC conversion
components and regulators, the BCM allows the Power Design
Engineer to employ a simple, low-profile design, which will
differentiate the end system without compromising on cost or
performance metrics.
• High End Computing Systems
• Automated Test Equipment
• Industrial Systems
• High Density Energy Systems
• Transportation
• Green Buildings and Microgrids
Size:
4.35 x 1.40 x 0.37in
[110.55 x 35.54 x 9.40mm]
Part Ordering Information
High
Side
Voltage
Range
Ratio
Max
High
Side
Max
Low
Side
Max
Low
Side
Product
Function
Package
Length
Package
Width
Package
Type
Product Grade
(Case Temperature)
Option Field
Voltage
Voltage Current
BCM
44
14
x
G0
F
44 40
y
zz
BCM =
Bus Converter
Module
02 = Chassis/PMBus
06 = Short Pin/PMBus
10 = Long Pin/PMBus
Length in
Width in
B = Board VIA
C = –20 to 100°C [a]
T = –40 to 100°C [a]
Internal Reference
Inches x 10 Inches x 10 V = Chassis VIA
[a] High temperature current derating may apply; See Figure 1, specified thermal operating area.
BCM® in a VIA™ Package
Page 1 of 43
Rev 1.2
01/2018