BCM4414xD1E13A2yzz  
Electrical Specifications (Cont.)  
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of  
-40°C TCASE 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.  
Attribute  
Symbol  
Conditions / Notes  
Min  
Typ  
Max  
Unit  
General Powertrain Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side) Cont.  
Effective HI Side Capacitance  
(Internal)  
CHI_INT  
CLO_INT  
Effective value at 384VHI_DC  
Effective value at 12VLO_DC  
0.4  
µF  
µF  
µF  
Effective LO Side Capacitance  
(Internal)  
238  
Excessive capacitance may drive module into  
short circuit protection  
Rated LO Side Capacitance (External) CLO_OUT_EXT  
1000  
Rated LO Side Capacitance (External),  
CLO_OUT_AEXT  
CLO_OUT_AEXT Max = N * 0.5 * CLO_OUT_EXT MAX, where  
N = the number of units in parallel  
Parallel Array Operation  
Powertrain Hardware Protection Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side)  
• These built-in powertrain protections are fixed in hardware and cannot be configured through PMBus®.  
• When duplicated in supervisory limits, hardware protections serve a secondary role and become active when supervisory limits are  
disabled through PMBus.  
Startup into a persistent fault condition. Non-latching  
fault detection given VHI_DC > VHI_UVLO+  
Auto Restart Time  
tAUTO_RESTART  
VHI_OVLO+  
VHI_OVLO-  
290  
430  
410  
360  
450  
440  
ms  
V
HI Side Overvoltage  
Lockout Threshold  
440  
430  
10  
HI Side Overvoltage  
Recovery Threshold  
V
HI Side Overvoltage  
Lockout Hysteresis  
VHI_OVLO_HYST  
tHI_OVLO  
V
HI Side Overvoltage Lockout  
Response Time  
100  
1
µs  
ms  
A
From powertrain active. Fast current limit protection  
disabled during soft-start  
HI Side Soft-Start Time  
tHI_SOFT-START  
ILO_OUT_OCP  
tLO_OUT_OCP  
ILO_OUT_SCP  
tLO_OUT_SCP  
tOTP+  
LO Side Overcurrent  
Trip Threshold  
135  
187  
125  
170  
3
210  
LO Side Overcurrent  
Response Time Constant  
Effective internal RC filter  
ms  
A
LO Side Short Circuit  
Protection Trip Threshold  
LO Side Short Circuit  
Protection Response Time  
1
µs  
°C  
Overtemperature  
Shutdown Threshold  
Internal  
BCM® in a VIA™ Package  
Page 7 of 43  
Rev 1.7  
08/2020  

与BCM4414VD1E13A2C02相关器件

型号 品牌 获取价格 描述 数据表
BCM4414VD1E13A2C06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2C10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2T02 VICOR

获取价格

DC DC CONVERTER 12V 1500W
BCM4414VD1E13A2T06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2T10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A3C02 VICOR

获取价格

DC/DC CONVERTER 12.8V 1600W
BCM4414VD1E13A3C06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A3C10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A3T02 VICOR

获取价格

DC/DC CONVERTER 12V DIGITAL
BCM4414VD1E13A3T06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter