BCM4414xG0F4440yzz  
Electrical Specifications (Cont.)  
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of  
–40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.  
Attribute  
Symbol  
Conditions / Notes  
Min  
Typ  
Max  
Unit  
General Powertrain Specification – Forward Direction Operation (High-Voltage Side to Low-Voltage Side) Cont.  
Effective HI-Side Capacitance  
(Internal)  
CHI_INT  
CLO_INT  
Effective value at 544VHI_DC  
Effective value at 34VLO_DC  
0.18  
50.6  
µF  
µF  
µF  
µF  
Effective LO-Side Capacitance  
(Internal)  
Excessive capacitance may drive module into short  
circuit protection  
Rated LO-Side Capacitance (External) CLO_OUT_EXT  
470  
Rated LO-Side Capacitance (External),  
CLO_OUT_AEXT  
CLO_OUT_AEXT Max = N • 0.5 • CLO_OUT_EXT MAX, where  
N = the number of units in parallel  
235  
Parallel Array Operation  
Powertrain Hardware Protection Specification – Forward Direction Operation (High-Voltage Side to Low-Voltage Side)  
• These built-in powertrain protections are fixed in hardware and cannot be configured through PMBus®.  
• When duplicated in supervisory limits, hardware protections serve a secondary role and become active when supervisory limits are  
disabled through PMBus.  
Start up into a persistent fault condition. Non-latching  
fault detection given VHI_DC > VHI_UVLO+  
Auto Restart Time  
tAUTO_RESTART  
VHI_OVLO+  
VHI_OVLO–  
900  
730  
700  
1000  
750  
730  
20  
1100  
780  
ms  
V
HI-Side Overvoltage  
Lockout Threshold  
HI-Side Overvoltage  
Recovery Threshold  
740  
V
HI-Side Overvoltage  
Lockout Hysteresis  
VHI_OVLO_HYST  
tHI_OVLO  
V
HI-Side Overvoltage  
Lockout Response Time  
10  
µs  
ms  
A
From powertrain active. Fast current limit protection  
disabled during soft start  
HI-Side Soft Start Time  
tHI_SOFT_START  
ILO_OUT_OCP  
tLO_OUT_OCP  
ILO_OUT_SCP  
tLO_OUT_SCP  
tOTP+  
1
2
LO-Side Overcurrent Trip Threshold  
42  
55  
50  
70  
LO-Side Overcurrent  
Response Time Constant  
Effective internal RC filter  
3.6  
ms  
A
LO-Side Short Circuit  
Protection Trip Threshold  
LO-Side Short Circuit  
Protection Response Time  
Short circuit protection (fast current limit) is  
disabled at start up [b]  
1
µs  
Overtemperature  
Shutdown Threshold  
Internal  
125  
°C  
[b] At start up, short circuit protection is disabled. Soft-start current limit provides protection against pre-existing output shorts. Soft-start mode ends when the  
output voltage reaches at least 90% of the final output voltage, and short-circuit protection is enabled when tHI_SOFT_START expires. Shorts that occur after  
soft start ends but before tHI_SOFT_START expires may cause damage to the product and will require external protection.  
BCM® in a VIA™ Package  
Page 7 of 44  
Rev 1.7  
10/2020  

与BCM4414BG0F4440T10相关器件

型号 品牌 获取价格 描述 数据表
BCM4414BH0E5035M06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414BH0E5035M10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414BH0E5035T06 VICOR

获取价格

Power Supply Module,
BCM4414BH0E5035T10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2C02 VICOR

获取价格

DC DC CONVERTER 12V 1500W
BCM4414VD1E13A2C06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2C10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2T02 VICOR

获取价格

DC DC CONVERTER 12V 1500W
BCM4414VD1E13A2T06 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter
BCM4414VD1E13A2T10 VICOR

获取价格

Isolated Fixed-Ratio DC-DC Converter