ATR28XXS Series
ATR2805S
Table II. Electrical performance Characteristics - continued
Symbol
Conditions
-55 C TC +125 C
Group A
Device
Types
Limits
Units
Subgroups
°
≤
≤
°
V
= 28VDC 5%, C = 0
±
L
IN
Min Max
Unless otherwise specified
Recovery time transient step
line changes 5, 8, 9
TTLINE
Input step 16V to/from
40VDC, IOUT = 6000mA
4,5,6
01
10
ms
Turn on overshoot
VTonOS
TonD
TrLF
IOUT =0 and 6000mA
IOUT =0 and 6000mA
4,5,6
4,5,6
4,5,6
01
01
01
500
25
25
mV pk
ms
ms
Turn on delay 10
Load fault recovery 5, 10
Notes to Specifications
1
2
3
4
Parameter guaranteed by line and load regulation tests.
Bandwidth guaranteed by design. Tested for 20KHz to 2.0MHz.
Output voltage measured at load with remote sense leads connected across load.
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of
the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing
as a short circuit during turn on.
5
6
Parameter shall be tested as part of design characterization and after design or process changes. There after parameters shall be
guaranteed to the limits specified in table II.
An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is the condition of maximum power dissipation.
7
8
9
Load step transition time between 2.0µs and 10µs.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load.
Input step transition time between 2.0µs and 10µs.
10 Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 2) while power is applied to the input.
www.irf.com
5