ATR28XXS Series
Device Screening
Requirement
MIL-STD-883 Method No Suffix
ES ꢀ
HB
CH
ꢀ
Temperature Range
Element Evaluation
Non-Destructive
Bond Pull
-20°C to +85°C -55°C to +125°C
-55°C to +125°C -55°C to +125°C
MIL-PRF-38534
2023
N/A
N/A
N/A
N/A
Class H
N/A
N/A
N/A
ꢁ
Internal Visual
Temperature Cycle
Constant Acceleration
PIND
2017
1010
Yes
Cond B
500 Gs
N/A
Yes
Cond C
3000 Gs
N/A
Yes
Cond C
3000 Gs
N/A
N/A
N/A
N/A
N/A
25°C
2001, Y1 Axis
2020
Burn-In
1015
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C
ꢂ
Final Electrical
( Group A )
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
25°C
-55°C, +25°C,
+125°C
N/A
-55°C, +25°C,
+125°C
10%
PDA
N/A
Cond A
N/A
N/A
Cond A, C
N/A
Seal, Fine and Gross
Radiographic
External Visual
Cond A, C
N/A
Cond A, C
N/A
2012
ꢁ
2009
Yes
Yes
Yes
Notes:
ꢀ Best commercial practice
ꢁ Sample tests at low and high temperatures
ꢂ -55°C to +105°C for AHE, ATO, ATW
Part Numbering
ATR 28 15 S F /CH
Screening Level
Model
(Please refer to Screening Table)
No Suffix, ES, HB, CH
Input Voltage
Nominal
28 = 28V
Package Style
F = Flange
Blank = Non-Flanged
Output Voltage
03R3 = 3.3V
05 = 5V
Output
S = Single
12 = 12V
15 = 15V
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 01/2007