AS1925/AS1926
Data Sheet - Electrical Characteristics
6 Electrical Characteristics
VCC = +0.55 to +1.8V, TAMB = -40 to +85ºC (unless otherwise specified). Typ values @ TAMB = +25ºC.
Table 4. Electrical Characteristics
Parameter 1
Symbol
Conditions
Min
Typ
Max
Units
Supply Voltage Range 2
VCC
0.75
1.80
V
VCC = 0.9V, No Load, Reset Not Asserted
3.5
4.5
12
ICC
Supply Current
VCC = 1.5V, No Load, Reset Not Asserted
12
µA
VCC = 1.8V, No Load, Reset Not Asserted
5
12
Suffix 14
Suffix 13
1.350
1.275
1.080
1.020
0.810
0.765
1.388
1.313
1.110
1.050
0.833
0.788
1.425
1.350
1.140
1.080
0.855
0.810
Suffix 11
Reset Threshold
(VCC Falling)
VTH
V
Suffix 10
Suffix 08
Suffix 07, TAMB = 0 to +85ºC
Reset Threshold
Hysteresis
VHYS
0.75
120
%VTH
µs
VCC Falling, Step Signal from (VTH + 10%)
to (VTH - 10%) within 1µs
VCC to Reset Delay
Suffix B
Suffix C
Suffix D
Suffix E
1
1.5
30
2
20
40
Reset Active Timeout
Period
tRP
ms
140
1120
210
1680
280
2240
0.3 ×
VCC
VIL
VIH
MRN Input Voltage 3
V
0.7 ×
VCC
MRN Minimum Input
Pulse Width
MRN driven from VCC to 0V 3
1
µs
MRN driven from VCC to 0V 3
MRN driven from VCC to 0V 3
MRN Glitch Rejection
MRN to Reset Delay
150
500
ns
ns
MRN Pullup Resistance
to VCC
10
20
26
kΩ
0.2 ×
VCC
VCC = 0.55V, ISINK = 10µA, Reset Asserted
VCC = 0.83V, ISINK = 80µA, Reset Asserted
VCC > VTH, Reset Not Asserted
RESETN Open-Drain
Output Voltage
VOL
ILEAK
VOL
V
0.2 ×
VCC
RESETN Open-Drain
Output Leakage Current
1
µA
0.2 ×
VCC
VCC = 0.55V, ISINK = 10µA, Reset Asserted
VCC = 0.83V, ISINK = 80µA, Reset Asserted
RESETN Push/Pull
Output Voltage
0.2 ×
VCC
V
VCC = 0.83V, ISOURCE = 40µA,
Reset Not Asserted
0.8 ×
VCC
VOH
www.austriamicrosystems.com
Revision 1.00
4 - 12