5秒后页面跳转
ARW-SH-106DM1 PDF预览

ARW-SH-106DM1

更新时间: 2024-11-19 00:50:59
品牌 Logo 应用领域
国兴 - GOODSKY /
页数 文件大小 规格书
2页 356K
描述
Relay

ARW-SH-106DM1 数据手册

 浏览型号ARW-SH-106DM1的Datasheet PDF文件第2页 
ARW  
MAIN FEATURE  
1. Switching capacity 15A in small size for  
exclusive automobile control relay switching  
box use.  
2. Standard and European Specification  
available to comply with various requirements.  
3. Various selections on types of sealing.  
4. Ambient temperature range covers from  
-40ºC to +85ºC.  
5. Comply with RoHS, REACH and ELV  
regulations.  
CONTACT RATING  
Load Type  
ARW (DM)  
5A 120VAC  
15A 12VDC  
15A  
ARW (D)  
5A 120VAC  
15A 12VDC  
15A  
Rated Load (Resistive)  
Rated Carrying Current  
Max. Allowable Voltage  
Max. Allowable Current  
Max. Allowable Power Force  
AC 120V  
DC 28V  
15A  
AC 120V  
DC 28V  
15A  
600VA  
600VA  
180W  
180W  
Contact Material  
Contact Form  
Ag Alloy  
SPST  
Ag Alloy  
SPDT  
APPLICATION  
Temperature Ran.g..e. ........... -40 +85°C  
Humidity Range .................. 45 85% RH.  
Coil Temperature Rise ....... 60°C Max.  
Vibration:  
Lighting Control, Door Lock Control, Power Window  
Control, Power Door Control, Sunroof Control  
........................  
Destruction  
10 to 55 to 10 Hz,0.75 mm single  
amplitude (1.5mm double amplitude)  
PERFORMANCE (AT INITIAL VALUE)  
Malfunction ........................  
Contact Resistance...............100 m Max.@1A, 6VDC  
Operate Time.........................10 mSec. Max.  
Release Time ........................10 mSec. Max.  
Dielectric Strength:  
Between Coil & Contact........1,000VAC at 50/60 Hz  
for one minute  
Between Contacts .................500VAC at 50/60 Hz  
for one minute  
Surge Strength ......................2,000V (between coil  
& contact 1.2x50μSec.)  
10 to 55 to 10 Hz,0.75 mm single  
amplitude (1.5mm double amplitude)  
Shock:  
Destruction ........................ 1,000 m/S2  
........................ 100 m/S2  
Malfunction  
Life Expectancy:  
Mechanical ......................... 107 Operations at No  
Load condition  
Electrical ............................. 105 Operations at Rated  
Resistive Load  
Insulation Resistance............100 Mega Min. at  
500VDC  
Weight ................................ About 10g  
Max. On/Off Switching:  
Electrical.................................6 Cycles per Minute  
Mechanical .............................300 Cycles per Minute  
SAFETY STANDARD & FILE NUMBER  
UL & C-UL .......................... E141060  
112