AC Current transducer AP-B10
IPN = 10 .. 400 A
Split core transducer for the electronic measurement AC waveforms
current, with galvanic isolation between the primary (High power) and
the secondary circuits (Electronic circuit). Switch selectable ranges
and RMS 0-5V and 0-10V switch selectable voltage output.
Electrical data
Primary Nominal Current
IPN (A.t.RMS)
Analogue Output Signal
VOUT (V)
Type
Features
10,25,50
0-5V or 0-10V
0-5V or 0-10V
0-5V or 0-10V
0-5V or 0-10V
AP 50 B10
AP 100 B10
AP 200 B10
AP 400 B10
· RMS output
50,75,100
100,150,200
200,300,400
· Split core type
· 5V & 10V switch selectable voltage
output
RL
VC
IC
Load resistance
³ 10
kW
Supply voltage
Current Consumption
Limitation of voltage output (0-10V)
Limitation of voltage output (0-5V)
Overloaded input current
+24 ±5% V DC
· DIN mounting & Panel mounting
· Eliminates insertion loss
· Switch selectable ranges
< 30
14
7
mA
V
V
no limitation
Accuracy-Dynamic performance data
Advantages
X
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (±1%)
< ±1
< ±0.5 % of IPN
< ±0.5 % of IPN
±1
±0.1
< 150
% of IPN
· Large aperture for cable up to
Ø18mm
e
VOLE
VOT
TCe
tr
· High isolation between primary and
secondary circuits
mV/K
%/K
m s
G
· Easy to mount
f
30 .. 2000 Hz
General data
Applications
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
-20 .. +60
-20 .. +85
90
IP20
5.5
5.5
600
V0
°C
°C
g
· Automation systems
Analog current reading for remote
monitoring (e.g. motor) and
software alarms.
Protection type
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative tracking index (Group I)
UL94 classification
m m
m m
V
· Panelmeters
Simple connection displays power
consumption.
Insulation category
Vb
Rated Voltage
300
V
with IEC 61010-1 standards and following conditions :
- Single insulation
- Over voltage category CAT III
- Pollution degree PD2
- None uniform field
Vd
Ve
Vw
R.m.s. voltage for AC insulation test, 50Hz, 1mn
R.m.s. voltage for partial discharge extinction @ 10pC 1.5
Peak impulse withstand voltage 1.2/50ms 6.1
5
kV
kV
kV
If insulated cable is used for the primary circuit, the voltage category
could be improved with the following table :
Cable insulation (primary)
HAR 05
Category
600V CAT III
1000V CAT III
HAR 07
041029/3
Notes : Installation and maintenance should be done with power supply disconnected.
The operator must have accrediation to install this material.
The users must take care of all protection gurantee against electrical shock.
.
LEM Components
www.lem.com