150 Watts
xppower.com
AML150 Series
•
•
•
•
•
•
•
High Power Density
Single Outputs from 12 V to 24 V
Universal Input
High Efficiency
0 °C to +70 °C Operating Temperature
Non-standard Connectors Available
International Safety Approvals
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
Efficiency
Isolation
• 88% min
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 2.0 A rms at 115 VAC,
1.0 A rms at 230 VAC
Inrush Current
Power Factor
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Switching Frequency
Power Density
MTBF
• 20-80 kHz variable
• 5.1 W/In3
• 0.95 typical
• >100 kHrs per MIL-HDBK-217F
(+25 °C ambient at full load)
Earth Leakage Current • 150 µA max at 115 VAC,
250 µA max at 230 VAC
Input Protection
• Internal 4 A fuse
• <1 W
Environmental
Standby Power
Consumption
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 60% power at +70 °C
Output
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 10-95% RH, non-condensing
• -20 °C to +80 °C
Output Voltage
• See table
• 3000 m
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• Not user-adjustable
• 30 g, 10 ms on 3 axes
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
•
2%
Vibration
• No minimum load required
• 5 s max at 100 VAC
Start Up Delay
EMC & Safety
Hold Up Time
• 3 ms minimum at 100 VAC
Emissions
• EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
Line Regulation
Load Regulation
Transient Response
•
0.5% maximum
• See table
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Surge
Conducted Immunity
Dips & Interruptions
Overload Protection
• 110-150%, auto recovery
• EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04%/°C
Safety Approvals
• EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark