120 Watts
xppower.com
AML120 Series
•
•
•
•
•
•
•
Energy Star Level V ≥ 18 V
CEC 2008 & EISA 2007 Compliant ≥15V
High Power Density
Single Outputs from 12 V to 48 V
High Efficiency
0 °C to +70 °C Operating Temperature
Non-standard Connectors Available
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
Efficiency
• 86ꢀ typical,
80ꢀ min for 12 V & 15 V models
Isolation
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
Inrush Current
Power Factor
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Switching Frequency
Power Density
MTBF
• 20-110 kHz variable
• 4.9 W/In3
• 0.98 typical at 115 VAC
Earth Leakage Current • 150 µA max at 115 VAC, 60 Hz
• >100 kHrs per MIL-HDBK-217F
250 µA max at 230 VAC, 50 Hz
Input Protection
• Internal 3 A fuse
• <0.75 W
Environmental
Standby Power
Consumption
Operating Temperature • 0 °C to +70 °C, derate from 100ꢀ power
at +50 °C to 60ꢀ power at +70 °C
Cooling
• Convection-cooled
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 10-95ꢀ RH, non-condensing
• -20 °C to +80 °C
Output
Output Voltage
• 12 to 48 VDC
• 3000 m
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• Not user-adjustable
• 30 g, 10 ms on 3 axes
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
•
2ꢀ
Vibration
• No minimum load required
• 2 s max at 115 VAC
EMC & Safety
Start Up Delay
Start Up Rise Time
Hold Up Time
• <80 ms at 115 VAC
Emissions
• EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
• 15 ms minimum at full load and 115 VAC
Line Regulation
Load Regulation
Transient Response
•
0.5ꢀ maximum
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2
• See table
• EN61000-3-3
• 4ꢀ max. deviation, recovery to within
1ꢀ in 500 µs for a 25ꢀ load change
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
Ripple & Noise
• 2ꢀ max pk-pk (see note 1)
Overvoltage Protection • 110-140ꢀ Vnom, recycle input to reset
Surge
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Conducted Immunity
Dips & Interruptions
• EN61000-4-11, 30ꢀ for 10 ms,
60ꢀ 100 ms, 100ꢀ 5000 ms,
Perf Criteria A, B, B
Overload Protection
• 110-150ꢀ, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04ꢀ/°C
Safety Approvals
• EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark