Series AMER60-Z
up to 1600mA | AC-DC LED driver
FEATURES:
• Universal Input: 90~305 Vac
• High Efficiency: Up to 90%
• Active Power Factor Correction
•
•
•
•
IP65/67 Design for outdoor application
Long Life, High reliability
Meet UL, CE Safety Requirement
5-year limited warranty
• Short Circuit / Open Circuit Protection
Models
Single output
Max Output
Output Voltage
Range
(V)
Output Current
(A)
Input Voltage
(VAC/Hz)
Efficiency
(%)
Model
Power
(W)
AMER60-42130Z
AMER60-42140Z
AMER60-42150Z
AMER60-42160Z
54.6
58.8
63.0
67.2
24-42
24-42
24-42
24-42
1.3
1.4
1.5
1.6
90-305/47-63
90-305/47-63
90-305/47-63
90-305/47-63
89
89
90
90
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Conditions
Typical
Maximum
1.0
Units
Arms
90 VAC, full load
115 VAC, cold start
277 VAC, cold start
40
60
Inrush current <2ms
A
Leakage current
Input dissipation
0.75
1.0
mA
W
No Load
Output Short
4.5
W
115 VAC, full load
277 VAC, full load
0.98
0.92
Power Factor
Input Fuse
2A / 300VAC
115 VAC, full load
277 VAC, full load
1.5
1.0
Sec.
Sec.
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise
Conditions
Typical
Maximum
Units
%
%
%
V p-p
A p-p
±5
±3
±5
LL to HL
Full Output Voltage Range
Full load
Full load, 16.7-20ms duration
LL to HL, full load at cold start,
% of rated output current
3
1.8
Output Current Ripple
Current Overshoot
10
0
%
Hold-up time (min)
ms
Minimum Load Voltage
See Models Table Above
Isolation Specifications
Parameters
Conditions
I/P – O/P
I/P – FG
Typical
Rated
3750
2000
500
Units
Tested I/O voltage
VAC
O/P – FG
Isolation Resistance
Isolation Capacitance
I/P – O/P, 500Vdc
VAC
pF
>100MΩ
2500
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only