Click on Series name for product info on aimtec.com
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Constant Current or Constant Voltage LED
Driver or Converter
Input range 90-305VAC/47-440Hz
High Efficiency up to 89%
115VAC Operating temperature -50 to 75°C
230VAC Operating temperature -55 to 75°C
Dimmable via resistive
Over Voltage Protection
Over Current Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Models
Single output
5 Year Limited Warranty
Max
Output
Efficiency
Output
Input
Voltage
(VAC/Hz)
Input
Output Voltage
(%)
Current
Model
Voltage Mode of Operation
(VDC)
Power
Range
③
115
230
277
(A)
①
③
VAC
VAC
VAC
(W)
(V)
Constant Current
87
87
86
86
85
85
89
88
88
88
87
87
89
89
88
88
87
87
AMER150-50300CAZ
AMER150-36420CAZ
AMER150-24630CAZ
150
150
36-50
24-36
12-24
0-3
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
②
Constant Voltage
Constant Current
0-4.16
0-6.3
②
Constant Voltage
Constant Current
151.2
②
Constant Voltage
Add Suffix “-F” No dimming option
①
Exceeding the maximum output power will permanently damage the converter
The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
②
option in this case.
③
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-saleAMER150-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from
conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial,
and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive
voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to
ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure
to identify excessive line surges violations prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
Typical
Maximum
2000
1000
900
Units
mA
mA
mA
A
Current (full load)
50
Inrush current <2ms (cold start)
Leakage current
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
75
90
0.25
3.5
A
A
mA
mA
0.98
0.94
0.92
3.5
Power factor
230 VAC
277 VAC
Recommended slow blow type
External fuse
Start-up time
A
ms
900
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
1 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only