Click on Series name for product info on aimtec.com
Series AMEPR10D-AZ
up to 0.7A | AC-DC LED driver
FEATURES:
AC-DC Constant current LED Driver
Input range 90-264VAC/47-440Hz
High Efficiency up to 81%
Operating temperature -20 to 80°C
Total Harmonic Distortion < 20%
5 Year Limited Warranty
Over Temperature Protection
IP20 and IP67 Case
Active PFC with TRIAC dimmable
SCP, Over Voltage Protection
Leading or Trailing Edge Triac
②
Models
Single output
No Load
Efficiency
(%)
Max
Output
Voltage
Range
(V)
Output
Current
(A)
Output
Voltage
(V max.)
Output
Power
Input Voltage
(VAC/Hz)
Model
115
230
①
(W)
VAC
VAC
②
②
②
②
②
②
AMEPR10D-5020AZ+Suffix
AMEPR10D-4025AZ+Suffix
AMEPR10D-3630AZ+Suffix
AMEPR10D-3035AZ+Suffix
AMEPR10D-1564AZ+Suffix
10
10
36-50
30-40
24-36
15-30
8-15
62
62
52
34
23
23
0.2
0.25
0.3
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
78
81
80
77
77
78
79
80
81
78
76
79
10.8
10.5
9.6
0.35
0.64
0.7
AMEPR10D-1270AZ+Suffix
①
8.4
5-12
Exceeding the maximum output power will permanently damage the converter.
②
Model Nomenclature for Ordering:
Add Suffix “-UD”
Universal AC input 90-264VAC (no TRIAC dimming option), IP20
Universal AC input 90-264VAC (no TRIAC dimming option), IP67
AC input 90-135VAC, IP20
Add Suffix “-UW”
Add Suffix “-110D”
Add Suffix “-110W”
Add Suffix “-220D”
AC input 90-135VAC, IP67
AC input 180-264VAC, IP20
Add Suffix “-220W”
AC input 180-264VAC, IP67
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR10D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115VAC
230VAC
Typical
15
Maximum
Units
Inrush current <2ms (cold start)
A
25
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
0.2
Leakage current
Current (Full Load)
Power Factor
mA
mA
0.25
110
55
0.9
0.9
External fuse (slow blow)
Start up time
Recommended slow blow Type
1
200
A
ms
www.aimtec.com
F 052.1e R3.P
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)