Click on Series name for product info on aimtec.com
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
FEATURES:
AC-DC Constant current LED Driver
Input range 90-277VAC/47-440Hz
High Efficiency up to 86%
Operating temperature -40 to 80°C
Dimmable via analog / 0-10Vdc / PWM
(C version see table)
Over Temperature Protection
Open frame
Power Factor Correction
SCP, Over Current Protection
5 Years Limited Warranty
Models
Single output
Max
Output
Voltage
Range (V)
Output
Current
(A)
Output
Power
(W) *
35
30.72
36
33.6
30
Input Voltage
Input Voltage
Efficiency
Model
(VAC/Hz)
(VDC)
(%)
AMEOR30-5070AZ
AMEOR30-4864AZ
AMEOR30-36100AZ
AMEOR30-24140AZ
AMEOR30-12250AZ
36-50
36-48
24-36
12-24
5-12
0.7
0.64
1
1.4
2.5
90-277/47-440
90-277/47-440
90-277/47-440
90-277/47-440
90-277/47-440
130-390
130-390
130-390
130-390
130-390
86
86
85
84
83
*Exceeding the maximum output power will permanently damage the converter
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to
part number when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEOR30-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
Typical
25
Maximum
Units
Inrush current <2ms
A
40
0.3
0.5
0.33
0.16
Leakage current
AC current
mA
A
0.99
0.97
Power Factor
External fuse
Start up time
Surge voltage
250V/1A
450
ms
V
2sec
440
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
±3
±1
±3
LL-HL
0-100% load
Load regulation
%
Ripple & Noise *
Hold-up time
20MHz Bandwidth
75
50
mV p-p
ms
Current adjustment range
Minimum Load Voltage
100-0
%
See the models table
* Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
www.aimtec.com
F 052.1e R3.J
Tel: +1 514 620 2722
1 of 15
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only