Series AM15WM-NZ
15 Watt | DC-DC Converter
FEATURES:
Super wide Input range 200-1500VDC
Operating temperature of -25 to +70°C
Input under voltage lockout
No minimum load required
High efficiency of up to 79%
I/O Isolation of 4000VAC
Over current and Over Voltage protection
Reversed connection protection
Models
Single output
Output
Voltage
(V)
Output
Current max
Max
Input Voltage
Isolation
(VAC)
Efficiency
(800VDC) (%)
Model
Capacitive
Load(uF)
2000
(V)
(A)
1.25
1
AM15WM-80012S-NZ
AM15WM-80015S-NZ
AM15WM-80024S-NZ
200-1500
200-1500
200-1500
12
15
24
4000
4000
4000
76
77
79
1200
470
0.625
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
800VDC
Typical
Maximum
Units
VDC
Voltage range
200-1500
130
30
200VDC input
800VDC input
1500VDC input
200VDC input
800VDC input
1500VDC input
Input current
mA
A
25
50
80
150
Inrush current <2ms
External fuse
Slow blow, 15A/1500VDC
Lockout ON
Lockout OFF
Full load
170-185
180-195
2
Input under voltage protection
Startup time*
VDC
s
*The cooling time between input under voltage ON and OFF is over 15s.
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
4000
Maximum
Maximum
Units
VAC
1 min
Output Specifications
Parameters
Conditions
Typical
Units
%
Voltage accuracy
±2
Line voltage regulation
Load voltage regulation
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
LL-HL, full load
0-100% load
±1
±1
% of Vin
%
Zener diode clamp
≥120
Continuous
Auto recovery
±0.02
Auto recovery
% of Iout
Temperature coefficient
Ripple & Noise
%/oC
mV p-p
20MHz Bandwidth
150
300
General Specifications
Parameters
Conditions
100% load
With derating
Typical
65
-25 to 70
-25 to 85
Maximum
Units
kHz
°C
°C
°C
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
95
Natural convection
www.aimtec.com
F 051e R14
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)