AH3382
Magnetic Characteristics (Notes 11 &12) (TA = -40°C to +125°C , VDD = 3.0V to 28V, unless otherwise specified.)
(1mT=10 Gauss)
Symbol
Parameter
Condition
Min
Typ
Max
Unit
VDD = 12V, TA = +25C
BOPS (South pole to part marking side for
SOT23 and SIP-3 (Ammo Pack), SIP-3
(Bulk Pack) packages;
South pole to the non-part marking side
for SC59 package. See diagram below)
-
55
-
Operation Point
TA = -40C to +125C
40
-
55
35
35
70
-
VDD = 12V, TA = +25C
TA = -40C to +125C
BRPS (South pole to part marking side for
SOT23 and SIP-3 (Ammo Pack), SIP-3
(Bulk Pack) packages;
South pole to the non-part marking side
for SC59 package. See diagram below)
Gauss
Release Point
20
50
-
20
20
-
VDD = 12V, TA = +25C
TA = -40C to +125C
Hysteresis (Note 13)
BHY (|BOPX|-|BRPX|)
15
25
Notes:
11. When power is initially turned on, VDD must be within its correct operating range (3.0V to 28V) to guarantee the output sampling. The output state is valid
after the start-up time of 10s typical from the operating voltage reaching 3V.
12. Typical values are defined at TA = +25C, VDD = 12V. Maximum and minimum values over the operating temperature range is not tested in production
but guaranteed by design, process control and characterization
13. Maximum and minimum hysteresis is guaranteed by design, process control and characterization.
Output
(Off-state)
VDD
BHY
Turn off
Turn on
(On-state)
VOUT_ON = VSAT
0 BRPS BOPS
( Magnetic Flux Density B )
S
S
S
Part mark
Part mark
Part mark
N
N
N
SC59
SOT23
SIP-3(Ammo Pack)
SIP-3(Bulk Pack)
4 of 14
www.diodes.com
May 2018
© Diodes Incorporated
AH3382
Document number: DS38921 Rev. 2 - 2