Type AFK_V, –55 °C to 105 °C, High Vibration
SMT Aluminum Electrolytic Capacitors - Lowest E.S.R., 105 °C
Low Impedance and Long-Life for Filtering, Bypassing and Power Supply Decoupling
Using a ruggedized construction, type AFK_V withstands a 30 G
vibration test and has 40ꢀ to 60ꢀ lower impedance, 30ꢀ to 50ꢀ
smaller case size and more than twice the life compared to general
purpose types. As the main countermeasure to vibration, the metal
case is inserted into a molded plastic retaining wall that surrounds
the part, keeping it firmly in place. Larger diameter leads provide
additional mechanical stability of the internal winding and a larger
soldering surface keeps the part firmly affixed to the PCB. Type
AFK_V is an excellent choice for power systems subjected to frequent
motion and vibration.
Highlights
• Withstands 30 G vibration test
• +105 °C, Up to 5000 ꢂour Load Life
• Capacitance Range: 10 µF to 6800 µF
• Voltage Range: 6.3 Vdc to 100 Vdc
Specifications
Capacitance Range
Capacitance Tolerance
Rated Voltage
10 µF to 6800 µF
20ꢀ ꢁ 120 ꢂz and +20 °C
6.3, 10, 16, 25, 35, 50, 63, 80 & 100 Vdc
–55 ºC to +105 ºC
Operating Temperature Range
Leakage Current
0.01 CV or 3 µA ꢁ +20 ºC, after two minutes (whichever is greater)
Ripple Current Multiplier
Frequency
50/60 Hz
120 Hz
1 kHz
10 kHz
100 kHz
0.70
.0.75
0.90
0.95
1.00
Dissipation Factor
6.3V
10 V
0.19
16 V
25 V
35 V
0.12
50 V
63 V
80 V
100 V
0.07
0.26
0.16
0.14
0.1
0.08
0.08
Add 0.02 per 1000 µF for values greater than 1000 µF
Low Temperature Impedance Ratio Characteristics at 120 Hz
Rated Voltage (Vdc)
Z (-25°C)/Z(+20°C)
6.3, 10, 16 25, 35, 50, 63, 80, 100
2
3
4
2
3
3
Z (-40°C)/Z(+20°C)
Z (-55°C)/Z(+20°C)
Life Test
2000 h ꢁ 105 °C, 8.0 — 10.0 mm dia.
5000 h ꢁ 105 °C, 12.5 — 18.0 mm dia.
∆ Capacitance 30ꢀ
DF: ≤ 200ꢀ of limit
DCL: ≤ 100ꢀ of limit
Shelf Test
1000 h ꢁ 105 °C
∆ Capacitance 30ꢀ
DF: ≤ 200ꢀ of limit
DCL: ≤ 100ꢀ of limit
Capacitors with the high vibration base will pass a 30 G acceleration test from 5
ꢂz to 2000 ꢂz with a max. amplitude of 5 mm (peak to peak) for 2 hours each in
the X,Y and Z directions for a total of 6 hours. During the last 30 minutes of the
test, the measured capacitance shall be stable. After the test the capacitor shall
meet the following:
High Vibration Test
∆C at 120 Hz - Capacitance value will be within 5ꢀ of the initial value.
There will be no significant change in appearance.
RoHS Compliant
Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8564 • Fax: (508)996-3830 • www.cde.com