254
254
255
255
255
255
255
255
2
RWv
RWv
RWv
RWv
RWv
RWv
RWv
RWv
Mask Low Rx Power Alarm Channel 2: Writing 1 Prevents IntL generation, Default = 0
Reserved
1-0
7
Mask High Rx Power Alarm Channel 1: Writing 1 Prevents IntL generation, Default = 0
Mask Low Rx Power Alarm Channel 1: Writing 1 Prevents IntL generation, Default = 0
Reserved
6
5-4
3
Mask High Rx Power Alarm Channel 0: Writing 1 Prevents IntL generation, Default = 0
Mask Low Rx Power Alarm Channel 0: Writing 1 Prevents IntL generation, Default = 0
Reserved
2
1-0
Receiver Output Amplitude Control Code Description
Control registers 228 through 233 permit output signal amplitude selection. Four bit code blocks (either bits 7 through
4 or 3 through 0 where bit 7 or 3 is the msb) are assigned to each channel. Codes 1xxx are reserved. Code 0111 calls for
full scale signal amplitude and code 0000 calls for minimum signal amplitude. See table below.
Code
Receiver Output Amplitude – No De-emphasis
Reference
Min
Nominal
Max
Units
1xxxb
0111b
0110b
0101b
0100b
0011b
0010b
0001b
0000b
Reserved
Full Scale
850
760
670
580
490
400
310
220
mVpp
mVpp
mVpp
mVpp
mVpp
mVpp
mVpp
mVpp
Default setting
Receiver Output De-emphasis Control Code Description
Control registers 234 through 239 permit output de-emphasis selection. Four bit code blocks (either bits 7 through 4 or
3 through 0 where bit 7 or 3 is the msb) are assigned to each channel.
Codes 1xxx are reserved.
Code 0111 calls for full scale, 6 dB, de-emphasis and code 0000 calls for no de-emphasis.
Intermediate code values yield intermediate de-emphasis levels
44