5秒后页面跳转
ADuM7642CRQZ PDF预览

ADuM7642CRQZ

更新时间: 2024-01-06 00:28:30
品牌 Logo 应用领域
亚德诺 - ADI 驱动程序和接口接口集成电路PC
页数 文件大小 规格书
20页 392K
描述
1 kV RMS Six-Channel Digital Isolators

ADuM7642CRQZ 技术参数

是否无铅:含铅是否Rohs认证:符合
生命周期:Active包装说明:SSOP,
针数:20Reach Compliance Code:compliant
ECCN代码:EAR99HTS代码:8543.70.99.60
风险等级:1.57Samacsys Confidence:4
Samacsys Status:ReleasedSamacsys PartID:421531
Samacsys Pin Count:20Samacsys Part Category:Integrated Circuit
Samacsys Package Category:Small Outline PackagesSamacsys Footprint Name:QSOP-20
Samacsys Released Date:2018-08-06 07:19:52Is Samacsys:N
接口集成电路类型:INTERFACE CIRCUITJESD-609代码:e3
长度:8.66 mm湿度敏感等级:1
功能数量:1最高工作温度:105 °C
最低工作温度:-40 °C封装代码:SSOP
峰值回流温度(摄氏度):260座面最大高度:1.75 mm
最大供电电压:5.5 V最小供电电压:3 V
标称供电电压:3.3 V温度等级:INDUSTRIAL
端子面层:Matte Tin (Sn)端子节距:0.64 mm
处于峰值回流温度下的最长时间:30宽度:3.91 mm
Base Number Matches:1

ADuM7642CRQZ 数据手册

 浏览型号ADuM7642CRQZ的Datasheet PDF文件第14页浏览型号ADuM7642CRQZ的Datasheet PDF文件第15页浏览型号ADuM7642CRQZ的Datasheet PDF文件第16页浏览型号ADuM7642CRQZ的Datasheet PDF文件第17页浏览型号ADuM7642CRQZ的Datasheet PDF文件第18页浏览型号ADuM7642CRQZ的Datasheet PDF文件第20页 
Data Sheet  
ADuM7640/ADuM7641/ADuM7642/ADuM7643  
The insulation lifetime of the ADuM7640/ADuM7641/  
ADuM7642/ADuM7643 depends on the voltage waveform type  
imposed across the isolation barrier. The iCoupler insulation  
structure degrades at different rates depending on whether the  
waveform is bipolar ac, unipolar ac, or dc. Figure 24, Figure 25,  
and Figure 26 illustrate these different isolation voltage  
waveforms.  
POWER CONSUMPTION  
The supply current at a given channel of the ADuM7640/  
ADuM7641/ADuM7642/ADuM7643 isolator is a function of  
the supply voltage, the data rate of the channel, and the output  
load of the channel.  
For each input channel, the supply current is given by  
IDDI = IDDI (Q)  
DDI = IDDI (D) × (2f fr) + IDDI (Q)  
f ≤ 0.5 fr  
f > 0.5 fr  
Bipolar ac voltage is the most stringent environment. The goal  
of a 50-year operating lifetime under the bipolar ac condition  
determines the Analog Devices recommended maximum  
working voltage.  
I
For each output channel, the supply current is given by  
I
I
DDO = IDDO (Q)  
f ≤ 0.5 fr  
In the case of unipolar ac or dc voltage, the stress on the insulation  
is significantly lower. This allows operation at higher working  
voltages while still achieving a 50-year service life. The working  
voltages listed in Table 18 can be applied while maintaining the  
50-year minimum lifetime, provided that the voltage conforms to  
either the unipolar ac or dc voltage case. Any cross-insulation  
voltage waveform that does not conform to Figure 25 or Figure 26  
should be treated as a bipolar ac waveform, and its peak voltage  
should be limited to the 50-year lifetime voltage value listed in  
Table 18.  
DDO = (IDDO (D) + (0.5 × 10−3) × CL × VDDO) × (2f − fr) + IDDO (Q)  
f > 0.5 fr  
where:  
DDI (D), IDDO (D) are the input and output dynamic supply currents  
per channel (mA/Mbps).  
DDI (Q), IDDO (Q) are the specified input and output quiescent  
I
I
supply currents (mA).  
f is the input logic signal frequency (MHz); it is half the input  
data rate, expressed in units of Mbps.  
fr is the input stage refresh rate (Mbps).  
CL is the output load capacitance (pF).  
The voltage presented in Figure 25 is shown as sinusoidal for  
illustration purposes only. It is meant to represent any voltage  
waveform varying between 0 V and some limiting value. The  
limiting value can be positive or negative, but the voltage cannot  
cross 0 V.  
V
DDO is the output supply voltage (V).  
To calculate the total VDD1 and VDD2 supply current, the supply  
currents for each input and output channel corresponding to  
RATED PEAK VOLTAGE  
VDD1 and VDD2 are calculated and totaled. Figure 10 and Figure 11  
0V  
show per-channel supply currents as a function of data rate for  
an unloaded output condition. Figure 12 shows the per-channel  
supply current as a function of data rate for a 15 pF output  
condition. Figure 13 through Figure 17 show the total VDD1 and  
Figure 24. Bipolar AC Waveform  
RATED PEAK VOLTAGE  
VDD2 supply current as a function of data rate for ADuM7640/  
ADuM7641/ADuM7642/ADuM7643 channel configurations.  
0V  
INSULATION LIFETIME  
Figure 25. Unipolar AC Waveform  
All insulation structures eventually break down when subjected to  
voltage stress over a sufficiently long period. The rate of insulation  
degradation depends on the characteristics of the voltage waveform  
applied across the insulation. In addition to the testing performed  
by the regulatory agencies, Analog Devices carries out an extensive  
set of evaluations to determine the lifetime of the insulation  
structure within the ADuM7640/ADuM7641/ADuM7642/  
ADuM7643 components.  
RATED PEAK VOLTAGE  
0V  
Figure 26. DC Waveform  
Analog Devices performs accelerated life testing using voltage  
levels higher than the rated continuous working voltage. Accel-  
eration factors for several operating conditions are determined.  
These factors allow calculation of the time to failure at the actual  
working voltage. The values shown in Table 18 summarize the peak  
voltage for 50 years of service life for a bipolar ac operating  
condition and the maximum working voltages. In many cases,  
the approved working voltage is higher than the 50-year service life  
voltage. Operation at these high working voltages can lead to  
shortened insulation life in some cases.  
Rev. 0 | Page 19 of 20  
 
 
 
 
 

与ADuM7642CRQZ相关器件

型号 品牌 描述 获取价格 数据表
ADuM7642CRQZ-RL7 ADI 1 kV RMS Six-Channel Digital Isolators

获取价格

ADUM7643 ADI 1 kV RMS 四通道数字隔离器(3/3通道方向性)

获取价格

ADuM7643ARQZ ADI 1 kV RMS Six-Channel Digital Isolators

获取价格

ADuM7643ARQZ-RL7 ADI 1 kV RMS Six-Channel Digital Isolators

获取价格

ADuM7643CRQZ ADI 1 kV RMS Six-Channel Digital Isolators

获取价格

ADuM7643CRQZ-RL7 ADI 1 kV RMS Six-Channel Digital Isolators

获取价格