5秒后页面跳转
ADUM5403CRWZ PDF预览

ADUM5403CRWZ

更新时间: 2024-02-21 11:45:31
品牌 Logo 应用领域
亚德诺 - ADI 转换器
页数 文件大小 规格书
28页 539K
描述
Quad-Channel, 2.5 kV Isolators with Integrated DC-to-DC Converter

ADUM5403CRWZ 技术参数

生命周期:Active包装说明:,
Reach Compliance Code:unknown风险等级:5.57
模拟集成电路 - 其他类型:ANALOG CIRCUITBase Number Matches:1

ADUM5403CRWZ 数据手册

 浏览型号ADUM5403CRWZ的Datasheet PDF文件第22页浏览型号ADUM5403CRWZ的Datasheet PDF文件第23页浏览型号ADUM5403CRWZ的Datasheet PDF文件第24页浏览型号ADUM5403CRWZ的Datasheet PDF文件第26页浏览型号ADUM5403CRWZ的Datasheet PDF文件第27页浏览型号ADUM5403CRWZ的Datasheet PDF文件第28页 
Data Sheet  
ADuM5401/ADuM5402/ADuM5403/ADuM5404  
Table 27 illustrates how isoPower devices can provide many combinations of data channel count and multiples of the single unit power.  
Table 27. Configurations for Power and Data Channels  
Number of Data Channels  
Power Unit  
0 Channels  
2 Channels  
4 Channels  
6 Channels  
1-Unit Power  
ADuM5000 master  
ADuM520x master  
ADuM5401 to ADuM5404 master  
ADuM5401 to ADuM5404 master  
ADuM121x  
2-Unit Power  
3-Unit Power  
ADuM5000 master  
ADuM5000 slave  
ADuM5000 master  
ADuM5000 slave  
ADuM5000 slave  
ADuM5000 master  
ADuM520x slave  
ADuM5000 master  
ADuM5000 slave  
ADuM520x slave  
ADuM5401 to ADuM5404 master  
ADuM520x slave  
ADuM5401 to ADuM5404 master  
ADuM520x slave  
ADuM5401 to ADuM5404 master  
ADuM5000 slave  
ADuM5000 slave  
ADuM5401 to ADuM5404 master  
ADuM520x slave  
ADuM5000 slave  
In the case of unipolar ac or dc voltage, the stress on the insulation  
is significantly lower. This allows operation at higher working  
voltages while still achieving a 50-year service life. The working  
voltages listed in Table 20 can be applied while maintaining the  
50-year minimum lifetime, provided that the voltage conforms  
to either the unipolar ac or dc voltage cases.  
INSULATION LIFETIME  
All insulation structures eventually break down when subjected to  
voltage stress over a sufficiently long period. The rate of insulation  
degradation is dependent on the characteristics of the voltage  
waveform applied across the insulation. In addition to the testing  
performed by the regulatory agencies, Analog Devices carries  
out an extensive set of evaluations to determine the lifetime  
of the insulation structure within the ADuM5401/ADuM5402/  
ADuM5403/ADuM5404 devices.  
Any cross-insulation voltage waveform that does not conform  
to Figure 31 or Figure 32 should be treated as a bipolar ac wave-  
form and its peak voltage limited to the 50-year lifetime voltage  
value listed in Table 20. The voltage presented in Figure 32 is  
shown as sinusoidal for illustration purposes only. It is meant to  
represent any voltage waveform varying between 0 V and some  
limiting value. The limiting value can be positive or negative,  
but the voltage cannot cross 0 V.  
Analog Devices performs accelerated life testing using voltage levels  
higher than the rated continuous working voltage. Acceleration  
factors for several operating conditions are determined. These  
factors allow calculation of the time to failure at the actual working  
voltage. The values shown in Table 20 summarize the peak voltage  
for 50 years of service life for a bipolar ac operating condition  
and the maximum CSA/VDE approved working voltages. In  
many cases, the approved working voltage is higher than the  
50-year service life voltage. Operation at these high working  
voltages can lead to shortened insulation life in some cases.  
RATED PEAK VOLTAGE  
0V  
Figure 30. Bipolar AC Waveform  
The insulation lifetime of the ADuM5401/ADuM5402/  
ADuM5403/ADuM5404 devices depends on the voltage wave-  
form type imposed across the isolation barrier. The iCoupler  
insulation structure degrades at different rates depending on  
whether the waveform is bipolar ac, unipolar ac, or dc. Figure 30,  
Figure 31, and Figure 32 illustrate these different isolation  
voltage waveforms.  
RATED PEAK VOLTAGE  
0V  
Figure 31. DC Waveform  
RATED PEAK VOLTAGE  
Bipolar ac voltage is the most stringent environment. The goal  
of a 50-year operating lifetime under the bipolar ac condition  
determines the maximum working voltage recommended by  
Analog Devices.  
0V  
NOTES:  
1. THE VOLTAGE IS SHOWN AS SINUSOIDAL FOR ILLUSTRATION  
PURPOSES ONLY. IT IS MEANT TO REPRESENT ANY VOLTAGE  
WAVEFORM VARYING BETWEEN 0V AND SOME LIMITING VALUE.  
THE LIMITING VALUE CAN BE POSITIVE OR NEGATIVE, BUT THE  
VOLTAGE CANNOT CROSS 0V.  
Figure 32. Unipolar AC Waveform  
Rev. C | Page 25 of 28  
 
 
 
 
 

与ADUM5403CRWZ相关器件

型号 品牌 描述 获取价格 数据表
ADUM5403CRWZ1 ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403CRWZ2 ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403CRWZRL ADI SPECIALTY ANALOG CIRCUIT, PDSO16, ROHS COMPLIANT, MS-013AA, SOIC-16

获取价格

ADUM5403W ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403WCRWZ ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格

ADUM5403WCRWZ-1 ADI Quad-Channel Isolators with Integrated DC-to-DC Converter

获取价格