Data Sheet
ADuM5200/ADuM5201/ADuM5202
PACKAGE CHARACTERISTICS
Table 14. Thermal and Isolation Characteristics
Parameter
Symbol Min Typ Max Unit Test Conditions
RESISTANCE AND CAPACITANCE
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
RI-O
CI-O
CI
102
2.2
4.0
45
Ω
pF
pF
f = 1 MHz
IC Junction to Ambient Thermal Resistance θJA
°C/W Thermocouple located at the center of the package
underside; test conducted on a 4-layer board with
thin traces 3
THERMAL SHUTDOWN
Threshold
Hysteresis
TSSD
TSSD-HYS
150
20
°C
°C
TJ rising
1 This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
3 Refer to the Power Considerations section for thermal model definitions.
REGULATORY INFORMATION
The ADuM5200/ADuM5201/ADuM5202 are approved by the organizations listed in Table 15. Refer to Table 20 and the Insulation Lifetime
section for more information about the recommended maximum working voltages for specific cross-insulation waveforms and insulation levels.
Table 15.
UL1
CSA
VDE (Pending)2
Recognized under UL 1577 component
recognition program1
Approved under CSA Component
Acceptance Notice #5A
Certified according to IEC 60747-5-2
(VDE 0884, Part 2):2003-012
Single protection, 2500 V rms
isolation voltage
Testing was conducted per CSA 60950-1-07
Basic insulation, 560 VPEAK
and IEC 60950-1 2nd Ed. at 2.5 kV rated voltage
Basic insulation at 600 V rms (848 VPEAK
)
working voltage
Reinforced insulation at 250 V rms (353 VPEAK
working voltage
)
File E214100
File 205078
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM5200/ADuM5201/ADuM5202 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage
detection limit = 10 μA).
2 In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM520x is proof tested by applying an insulation test voltage ≥ 1590 VPEAK for 1 second (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 16. Critical Safety-Related Dimensions and Material Properties
Parameter
Symbol Value
Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage
Minimum External Air Gap
2500
8.0
V rms 1-minute duration
L(I01)
L(I02)
mm
Distance measured from input terminals to output
terminals; shortest distance through air along the
PCB mounting plane, as an aid to PC board layout
Minimum External Tracking (Creepage)
7.6
mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Distance (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
0.017 min mm
Distance through insulation
DIN IEC 112/VDE 0303, Part 1
Material group (DIN VDE 0110, 1/89, Table 1)
CTI
>175
IIIa
V
Rev. B | Page 9 of 28