ADS125H01
SBAS999A – JUNE 2019 – REVISED AJADNSUA1R2Y5H200211
SBAS999A – JUNE 2019 – REVISED JANUARY 2021
www.ti.com
ADS125H01 ±20-V Input, 40-kSPS, 24-Bit, Delta-Sigma ADC
1 Features
3 Description
•
•
•
±20-V input, 24-bit delta-sigma ADC
The ADS125H01 is a ±20-V input, 24-bit, delta-sigma
(ΔΣ) analog-to-digital converter (ADC). The ADC
features a low-noise programmable gain amplifier
(PGA), a clock oscillator, and signal or reference out-
of-range monitors.
Programmable data rate: 2.5 SPS to 40 kSPS
High-voltage, 1-GΩ input impedance PGA:
– Differential input range: up to ±20 V
– Absolute input range: up to ±15.5 V
– Programmable attenuation and gain:
The integration of a wide input range, ±18-V supply
PGA and an ADC into a single package reduces
board area up to 50% compared to discrete solutions.
•
0.125 to 128
•
High-performance ADC:
– Noise: 45 nVRMS (gain = 128, 20 SPS)
– CMRR: 105 dB
– 50-Hz and 60-Hz rejection: 95 dB
– Offset drift: 10 nV/°C
– Gain drift: 1 ppm/°C
– INL: 2 ppm
Programmable attenuation and gain of 0.125 to 128
(corresponding to an equivalent input range from
±20 V to ±20 mV) eliminates the need for an external
attenuator or external gain stages. A 1-GΩ minimum
input impedance reduces error resulting from sensor
loading. Additionally, the low-noise and low-drift
performance allow direct connections to strain-gauge
bridge and thermocouple sensors that are affected by
high common-mode voltage.
•
•
Integrated features and diagnostics:
– Internal oscillator
– Signal and reference voltage monitors
– Cyclic redundancy check (CRC)
Power supplies:
– AVDD: 4.75 V to 5.25 V
– DVDD: 2.7 V to 5.25 V
– HVDD: ±5 V to ±18 V
The digital filter is programmable over a wide range
from 2.5 SPS to 40 kSPS. Attenuation of 50-Hz and
60-Hz line cycle noise for data rates ≤ 50 SPS or
60 SPS reduces measurement error. In most data
rates, the filter provides no-latency conversion data
for high data throughput during external channel
sequencing.
•
•
Operating temperature: –40°C to +125°C
5-mm × 5-mm VQFN package
The ADS125H01 is housed in a 5-mm × 5-mm VQFN
package and is fully specified over the –40°C to
+125°C temperature range.
2 Applications
•
•
•
PLC analog input modules:
– Voltage (±10 V or 0 V to 5 V)
– Current (4 mA to 20 mA with shunt)
Data acquisition (DAQ):
– High common-mode voltage inputs
– High-side current measurement
Battery tests
Device Information (1)
PART NUMBER
PACKAGE
BODY SIZE (NOM)
ADS125H01
VQFN (32)
5.00 mm × 5.00 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
5 V (D)
5 V (A)
15 V
START
RESET
DRDY
ADS125H01
Control
REFP
REFN
CS1
Buf
Monitor
CS2
Serial
Interface
(CRC)
DIN
AINP
AINN
24-Bit
ûꢀ ADC
Digital
Filter
DOUT/DRDY
SCLK
PGA
Monitor
-15 V
Clock
Mux
Oscillator
CLKIN
(D)
(A)
Functional Block Diagram
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
Product Folder Links: ADS125H01
Copyright © 2021 Texas Instruments Incorporated
Submit Document Feedback
1