55W Single Output with 5V,4A DC-DC Converter
ADS-55 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION
MODEL
ADS-5512
ADS-5524
OUTPUT NUMBER
CH1
12V
CH2
5V
CH1
CH2
5V
DC VOLTAGE
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
3A
3A
2A
2A
0 ~ 4A
51W
0 ~ 4A
0 ~ 2.5A
58W
0 ~ 4A
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
100mVp-p
CH1:21.6 ~ 26.4V
1.0%
100mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CH1:10.8 ~ 13.2V
VOLTAGE TOLERANCE Note.3 1.0%
3.0%
3.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
800ms, 50ms/230VAC
1600ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
80ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
74%
16ms/115VAC at full load
124 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
74%
INPUT
1.6A/115VAC
1A/230VAC
COLD START 20A/115VAC
<1mA / 240VAC
40A/230VAC
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:27.6 ~ 32.4V
PROTECTION
ENVIRONMENT
CH1:13.8 ~ 16.2V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0~50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
276.3K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.57Kg; 24pcs/13.7Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ADS-55-SPEC 2008-10-08