Data Sheet
ADE7912/ADE7913
REGULATORY APPROVALS (PENDING)
The ADE7912/ADE7913 are pending approval by the organizations listed in Table 2. Refer to Table 8 and the Insulation Lifetime section
for more information about the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 2. Regulatory Approvals
UL
CSA
VDE
Recognized Under UL 1577
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN VDE V 0884-102
(VDE V 0884-10):2006-12
Component Recognition Program1
Single Protection, 5000 V rms Isolation Basic insulation per IEC 61010-1, 400 V rms (564 V
Voltage peak) maximum working voltage
Reinforced insulation, 846 V peak
1 In accordance with UL 1577, each ADE7912/ADE7913 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit
= 10 µA).
2 In accordance with DIN V VDE V 0884-10, each ADE7912/ADE7913 is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge
detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 3. Critical Safety Related Dimensions and Material Properties
Parameter
Symbol Value
Unit
V rms
mm
Test Conditions/Comments
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
5000
1-minute duration
L(l01)
L(l02)
8.3
Distance measured from input terminals to output
terminals, shortest distance through air along the
PCB mounting plane, as an aid to PCB layout
Measured from input terminals to output terminals,
shortest distance path along body
Minimum External Tracking (Creepage)
8.3
mm
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
0.017 min mm
Insulation distance through insulation
IEC 60112
Material group (DIN VDE 0110, 1/89, Table 1)
CTI
>600
II
V
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
The ADE7912/ADE7913 are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is
ensured by the protective circuits.
Table 4. VDE Characteristics
Description
Test Conditions/Comments
Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
I to IV
I to IV
I to III
40/105/21
2
VIORM
Vpd(m)
846
1592
V peak
V peak
VIORM × 1.875 = Vpd(m), 100% production test, tini =
tm = 1 sec, partial discharge < 5 pC
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
Vpd(m)
VIORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec, partial
discharge < 5 pC
VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec, partial
discharge < 5 pC
1273
1018
V peak
V peak
After Input and/or Safety Tests Subgroup 2
and Subgroup 3
Highest Allowable Overvoltage
Surge Isolation Voltage
VIOTM
VIOSM
6000
6000
V peak
V peak
VPEAK = 10 kV, 1.2 µs rise time, 50 µs, 50% fall time
Safety Limiting Values
Maximum value allowed in the event of a failure
(see Figure 4)
Maximum Junction Temperature
Total Power Dissipation at 25°C
Insulation Resistance at TS
TS
PS
RS
150
2.78
>109
°C
W
Ω
VIO = 500 V
Rev. 0 | Page 7 of 44