AD9559
Data Sheet
SPECIFICATIONS
Minimum (min) and maximum (max) values apply for the full range of supply voltage and operating temperature variations. Typical (typ)
values apply for VDD3 = 3.3 V; VDD = 1.8 V; TA= 25°C, unless otherwise noted.
SUPPLY VOLTAGE
Table 1.
Parameter
SUPPLY VOLTAGE
VDD3
Min
Typ
Max
Unit Test Conditions/Comments
3.135 3.30
1.71 1.80
3.465
1.89
V
V
VDD
SUPPLY CURRENT
The test conditions for the maximum (max) supply current are at the maximum supply voltage found in Table 1.
The test conditions for the typical (typ) supply current are at the typical supply voltage found in Table 1.
The test conditions for the minimum (min) supply current are at the minimum supply voltage found in Table 1.
Table 2.
Parameter
Min
Typ
Max
Unit Test Conditions/Comments
SUPPLY CURRENT FOR TYPICAL CONFIGURATION
Typical values are for the Typical Configuration
parameter listed in Table 3
IVDD3
IVDD
34
253
42
316
50
380
mA
mA
SUPPLY CURRENT FOR ALL BLOCKS RUNNING
CONFIGURATION
Maximum values are for the All Blocks Running
parameter listed in Table 3
IVDD3
IVDD
75
256
94
320
113
384
mA
mA
Rev. 0 | Page 4 of 120