AD8386
OPERATING TEMPERATURE RANGE
The maximum operating junction temperature is 150°C. The
junction temperature trip point of the thermal protection
circuit is 165°C. Production tests guarantee a minimum
junction temperature trip point of 125°C.
3.00
2.75
2.50
2.25
2.00
1.75
1.50
1.25
1.00
STILL AIR
200LFM
400LFM
Consequently, the maximum guaranteed operating junction
temperature is 125°C when the thermal protection circuit is
enabled and 150°C when the thermal protection circuit is
disabled.
720p HDTV
QUIESCENT
To ensure operation within the specified operating temperature
range, it is necessary to limit the maximum power dissipation as
OVERLOAD
PROTECTION
TJMAX −TA
ENABLED
40
45
70
50
75
55
80
60
85
65
90
70
75
80
85
90
95
PDMAX
≈
Airflow in lfm 0.59
)
DISABLED
65
95 100 105 110 115 120
θJA Still Air − 0.09×
(
AMBIENT TEMPERATURE (°C)
Figure 2. Maximum Power Dissipation vs. Temperature
The AD8386 is on a 4-layer JEDEC PCB with a thermally
optimized landing pattern with 16 vias.
The quiescent power dissipation of the AD8386 is 1.4 W.
When driving a 12-channel 720p HDTV panel with an input
capacitance of 150 pF, the AD8386 dissipates 1.66 W when
displaying 1 pixel wide alternating white and black vertical lines
generated by a standard 720p HDTV input video.
Conditions include the following:
• AVCC = 15.5 V
• DVCC = 3.3 V
• VFS = 5 V
• CL = 150 pF
• fPIXEL = 74.25 MHz
• Black-to-white transition = 4 V
• Active video time = 75%
Figure 2 shows these power dissipations.
Rev. 0 | Page 7 of 20