Surge Arrester
A81-A500X
2-Electrode-Arrester
Ordering code: B88069X1490S102
DC spark-over voltage 1) 2)
Impulse spark-over voltage
500
± 20
V
%
at 100 V/µs - for 99 % of measured values
< 1000
< 900
V
V
- typical values of distribution
at 1 kV/µs
- for 99 % of measured values
- typical values of distribution
< 1100
< 1000
V
V
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current (wave 8/20 µs)
20
25
kA
kA
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles)
20
100
A
A
Insulation resistance at 100 Vdc
Capacitance at 1 MHz
> 10
GΩ
< 1.5
pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 10
~ 0.8
~ 60
V
A
V
Weight
~ 1.5
g
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue
-40 ... +90
40/ 90/ 21
°C
500 YY O
500
YY
O
- Nominal voltage
- Year of production
- Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
2)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM
Issue 04, 18.04.2002
Page 1 of 2