SN54ALS373A, SN54AS373, SN74ALS373A, SN74AS373
OCTAL TRANSPARENT D-TYPE LATCHES
WITH 3-STATE OUTPUTS
SDAS083C – APRIL 1982 – REVISED MARCH 2002
absolute maximum ratings over operating free-air temperature range (SN54ALS373A,
†
SN74ALS373A) (unless otherwise noted)
Supply voltage, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I
Voltage applied to any output in the high state or power-off state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Package thermal impedance, θ (see Note 1): DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58°C/W
JA
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69°C/W
NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60°C/W
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
SN54ALS373A
SN74ALS373A
MIN NOM MAX
UNIT
MIN NOM
MAX
V
V
V
Supply voltage
4.5
2
5
5.5
4.5
2
5
5.5
V
V
CC
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
Operating free-air temperature
IH
0.7
–1
0.8
–2.6
24
V
IL
I
I
mA
mA
°C
OH
12
OL
T
A
–55
125
0
70
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
SN54ALS373A SN74ALS373A
UNIT
MIN
MAX
MIN
MAX
f
t
t
t
Clock frequency
MHz
ns
clock
Pulse duration, LE high
Setup time, data before LE↓
Hold time, data after LE↓
12
10
7
10
10
7
w
ns
su
h
ns
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265