5秒后页面跳转
80L09C PDF预览

80L09C

更新时间: 2024-11-24 14:50:31
品牌 Logo 应用领域
库柏 - COOPER 电路保护
页数 文件大小 规格书
3页 92K
描述
Electric Fuse, Fast Blow, 80A, 600VAC, 250VDC, 200000A (IR), Inline/holder

80L09C 技术参数

生命周期:TransferredReach Compliance Code:unknown
风险等级:5.76Is Samacsys:N
熔断特性:FAST主体高度:60 mm
主体长度或直径:21.4 mm电路保护类型:ELECTRIC FUSE
安装特点:INLINE/HOLDER物理尺寸:21.4mm x 60mm
额定分断能力:200000 A额定电流:80 A
额定电压(交流):600 V额定电压(直流):250 V
参考标准:CSA; IEC表面贴装:NO
端子形状:TAB/BLADEBase Number Matches:1

80L09C 数据手册

 浏览型号80L09C的Datasheet PDF文件第2页浏览型号80L09C的Datasheet PDF文件第3页 
HRCII CURRENT LIMITING FUSES  
600V a.c. or less, 250V d.c. 200,000 A.I.R. to CSA C22.2 No. 106 M92  
Edison HRCII Fuses  
- Engineered for long life reliable protection.  
- Non deteriorating silver plated links.  
- High grade ceramic bodies.  
For full “no damage” protection under all fault conditions  
(Type 2 Coordination - per IEC 947-4), and to avoid nui-  
sance fuse operation, the fuse, relay and contactor charac-  
teristics must be considered together to ensure that:  
- the contactor is protected at all times  
- Plated external metalwork.  
- Interrupting rating certified to 200,000 Amps RMS sym-  
metrical, to CSA C22.2 No. 106M1992.  
- HRCII fuse manufacturing is certified to ISO 9002 (1987)  
standard.  
- the overload relay operates before the fuse (up to the  
relay’s safe interrupting limit), or  
- the fuse safely clears the circuit and limits high level  
fault currents to prevent damage to the relay or to the  
contactor.  
Applications  
HRCII fuses are often used to protect motor control circuits,  
together with contactors and overload protection relays.  
This is particularly necessary in the case of IEC style con-  
tactors, which require more accurate coordination to ensure  
optimum system reliability.  
In this application overload protection of the installation is  
provided by the thermal overload relay, and the fuses are  
usually rated higher than the motor full load current to avoid  
nuisance blowing under starting inrush currents.  
In addition CSA certified, Edison HRCII fuses are also test-  
ed and certified to IEC and British standards. IEC269:2 and  
BS88:2 include tightly specified characteristics to ensure full  
interchangeability with other manufacturers HRCII fuses  
certified to these standards.  
This arrangement allows the use of a fast-acting *fuse char-  
acteristic which ensures excellent short-circuit current and  
energy limiting for optimum protection.  
For further information on fuse selection and coordination  
contact your local Edison Fusegear representative.  
*CSA defined HRCII characteristics inherently give more time delay than  
HRCI fast acting fuses.  
Cross Reference  
AMPERE  
RATING  
2-30  
40-60  
80-100  
80-100+  
125-200  
125-200+  
250-400  
250-400+  
450-600  
EDISON  
H07C  
K07C  
L14C  
L09C  
M09C  
M14C  
P11C  
P09C  
R11C  
DORMAN*  
AAO  
BAO  
CEO  
CD  
DD  
DEO  
EF  
GEC/ENGLISH  
FUSETEK  
2CO  
2CO  
2CO  
2CM  
2CC  
2CM  
2CC  
2CM  
2CC  
GOULD  
BUSSMANN  
SIEMENS  
3NW211  
2NW212  
3NW213  
2NW222  
3NW223  
3NW214  
3NW231  
3NW224  
3NW233  
CIA  
CIS  
CCP  
CC  
FES, GIA  
FES, GIS  
FES, GCP  
FESC, GC  
FESC, GF  
FES, GFP  
FESC, GM  
FESF, GMF  
FESC, GLM  
CGL  
CGL  
CGL  
CGL  
CGL  
CGL  
CF  
CFP  
CM  
CMF  
CLM  
ED  
FF  
*HRCII fuses manufactured by Dorman Smith now available as Edison.  
+HRCII-MISC.  
102  

与80L09C相关器件

型号 品牌 获取价格 描述 数据表
80L09CB ETC

获取价格

Fuse
80-L10 JST

获取价格

Ring tongue terminal (R-type, Non-insulated)
80-L12 JST

获取价格

Ring tongue terminal (R-type, Non-insulated)
80L14-660 COOPER

获取价格

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
80L14C COOPER

获取价格

Electric Fuse, Fast Blow, 80A, 600VAC, 250VDC, 200000A (IR), Inline/holder
80L14CB ETC

获取价格

Fuse
80L186EA INTEL

获取价格

16-BIT HIGH-INTEGRATION EMBEDDED PROCESSORS
80L186EB INTEL

获取价格

16-BIT HIGH-INTEGRATION EMBEDDED PROCESSORS
80L186EB16 INTEL

获取价格

16-BIT HIGH-INTEGRATION EMBEDDED PROCESSORS
80L186EC ETC

获取价格

16-BIT HIGH-INTEGRATION EMBEDDED PROCESSORS