74LVC14A
Absolute Maximum Ratings (Note 4) (@TA = +25°C, unless otherwise specified.)
Symbol
Description
Rating
Unit
KV
KV
V
ESD HBM
Human Body Model ESD Protection
2
1
ESD CDM
Charged Device Model ESD Protection
Machine Model ESD Protection
ESD MM
VCC
VI
200
Supply Voltage Range
-0.5 to 6.5
-0.5 to 6.5
-0.5 to 6.5
-0.3 to VCC +0.5
-50
V
Input Voltage Range
V
VO
Voltage applied to output in high impedance or IOFF state
Voltage applied to output in high or low state
V
VO
V
IIK
Input Clamp Current
VI < 0
mA
mA
mA
mA
°C
°C
mW
IOK
Output Clamp Current VO < 0
Continuous output current
-50
IO
50
Continuous current through VDD or GND
Operating Junction Temperature
Storage Temperature
±100
TJ
-40 to +150
-65 to +150
500
TSTG
PTOT
Total Power Dissipation
Note:
4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should
be within recommend values.
Recommended Operating Conditions (Note 5) (@TA = +25°C, unless otherwise specified.)
Symbol
VCC
Parameter
Conditions
Min
1.65
0
Max
5.5
Unit
V
Supply Voltage
VI
Input Voltage
5.5
V
VCC
5.5
Active Mode
VCC = 0V; Power Down Mode
0
V
VO
Output Voltage
0
V
TA
Operating free-air temperature
-40
+125
ºC
Note: 5. Unused inputs should be held at VCC or Ground.
3 of 10
www.diodes.com
July 2012
© Diodes Incorporated
74LVC14A
Document number: DS35262 Rev. 3 - 2