74HC594
Functional Description and Timing Diagram
Control
STR
SHCP STCP
Input
Output
Function
SHR
L
DS
X
Q7S
L
Qn
NC
L
X
L
X
X
X
X
X
L
Clear Shift Register
X
X
NC
Q6S
NC
Q6S
Clear Storage Register
H
X
H
H
H or L
X
NC
Qs
QnS
Loads DS into shift register stage 0. All QS shifted
H
H
Contents of shift register moved to starge register all QS -> QN
Shift Register one pulse count ahead of storage register.
H or L
H=HIGH voltage state
L=LOW voltage state
=LOW to HIGH transition
X= don’t care – high or low (not floating)
NC= No change
SHCP
DS
STCP
SHR
STR
Q0
Q1
Q6
Q7
Q7S
Absolute Maximum Ratings (Note 4) (@TA = +25°C, unless otherwise specified.)
Symbol
ESD HBM
ESD CDM
ESD MM
VCC
Description
Human Body Model ESD Protection
Rating
Unit
KV
KV
V
2
Charged Device Model ESD Protection
Machine Model ESD Protection
Supply Voltage Range
1
200
-0.5 to +7.0
V
Input Voltage Range
-0.5 to +7.0
V
VI
Voltage applied to output in high or low state
V
Vo
-0.3 to VCC +0.5
-20
20
mA
mA
mA
mA
mA
mA
mA
mA
°C
IIK
Input Clamp Current
Input Clamp Current
VI < -0.5V
VI > Vcc +0.5V
IIK
-20
IOK
IOK
Output Clamp Current VO <-0.5V
20
Output Clamp Current VO > VCC + 0.5V
Q7 standard output
Qn bus driver outputs
±25
Continuous output current
IO
±35
Continuous current through Vcc
Continuous current through GND
Operating Junction Temperature
Storage Temperature
70
ICC
IGND
TJ
-70
-40 to +150
-65 to +150
500
°C
TSTG
PTOT
Total Power Dissipation
mW
Note:
4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be
within recommend values.
3 of 10
www.diodes.com
June 2013
© Diodes Incorporated
74AHC594
Document number: DS35484 Rev. 3 - 2