NXP Semiconductors
74HC3G06; 74HCT3G06
Triple inverter with open-drain outputs
9. Recommended operating conditions
Table 6.
Recommended operating conditions
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
74HC3G06
74HCT3G06
Unit
Min
Typ
Max
6.0
Min
Typ
Max
5.5
VCC
VI
supply voltage
input voltage
2.0
5.0
4.5
5.0
V
V
V
0
-
6.0
0
-
5.5
VO
output voltage
ambient temperature
0
-
+25
-
VCC
+125
625
139
83
0
-
+25
-
VCC
Tamb
t/V
40
40
+125 C
input transition rise
and fall rate
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
-
-
-
-
-
-
-
139
-
ns/V
1.67
-
1.67
-
ns/V
ns/V
10. Static characteristics
Table 7.
Static characteristics
Voltages are referenced to GND (ground = 0 V). All typical values are measured at Tamb = 25 C.
Symbol Parameter
Conditions
40 C to +85 C
40 C to +125 C
Unit
Min
Typ[1]
Max
Min
Max
74HC3G06
VIH
HIGH-level input
voltage
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
1.5
1.2
2.4
3.2
0.8
2.1
2.8
-
-
1.5
-
-
V
V
V
V
V
V
3.15
3.15
4.2
-
4.2
-
VIL
LOW-level input
voltage
-
-
-
0.5
1.35
1.8
-
-
-
0.5
1.35
1.8
VOL
LOW-level output VI = VIH or VIL
voltage
IO = 20 A; VCC = 2.0 V
-
-
-
-
-
-
0
0
0.1
0.1
-
-
-
-
-
-
0.1
0.1
0.1
0.4
0.4
1.0
V
IO = 20 A; VCC = 4.5 V
IO = 20 A; VCC = 6.0 V
IO = 4.0 mA; VCC = 4.5 V
IO = 5.2 mA; VCC = 6.0 V
VI = VCC or GND; VCC = 6.0 V
V
0
0.1
V
0.15
0.16
-
0.33
0.33
0.1
V
V
II
input leakage
current
A
ILO
ICC
CI
output leakage
current
VI = VIL; VO = VCC or GND
-
-
-
-
-
5.0
10
-
-
-
-
10
20
-
A
A
pF
supply current
per input pin; VCC = 6.0 V;
VI = VCC or GND; IO = 0 A;
input capacitance
1.5
74HC_HCT3G06
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2013. All rights reserved.
Product data sheet
Rev. 4 — 19 December 2013
4 of 14