74HC164-Q100; 74HCT164-Q100
Nexperia
8-bit serial-in, parallel-out shift register
7. Limiting values
Table 4.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
VCC
IIK
Parameter
Conditions
Min
Max
+7
Unit
V
supply voltage
0.5
[1]
[1]
input clamping current
output clamping current
output current
VI < 0.5 V or VI > VCC + 0.5 V
VO < 0.5 V or VO > VCC + 0.5 V
0.5 V < VO < VCC + 0.5 V
-
20
20
25
50
mA
mA
mA
mA
mA
C
IOK
-
IO
-
ICC
supply current
-
IGND
Tstg
Ptot
ground current
50
65
-
-
storage temperature
total power dissipation
+150
500
[2]
mW
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SO14 package: Ptot derates linearly with 8 mW/K above 70 C.
For TSSOP14 packages: Ptot derates linearly with 5.5 mW/K above 60 C.
For DHVQFN14 packages: Ptot derates linearly with 4.5 mW/K above 60 C.
8. Recommended operating conditions
Table 5.
Recommended operating conditions
Voltages are referenced to GND (ground = 0 V)
Symbol Parameter Conditions
74HC164-Q100
74HCT164-Q100
Unit
Min
Typ
Max
6.0
Min
Typ
Max
5.5
VCC
VCC
+125
-
VCC
VI
supply voltage
2.0
5.0
4.5
5.0
V
input voltage
0
-
VCC
VCC
+125
625
139
83
0
-
V
VO
output voltage
0
-
0
-
V
Tamb
t/V
ambient temperature
input transition rise and fall rate VCC = 2.0 V
VCC = 4.5 V
40
+25
40
+25
C
-
-
-
-
-
-
-
-
ns/V
ns/V
ns/V
1.67
-
1.67
-
139
-
VCC = 6.0 V
74HC_HCT164_Q100
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 1 — 16 August 2013
5 of 18