Nexperia
74AUP1G04
Low-power inverter
Symbol Parameter
Conditions
Min
Typ
Max
Unit
Tamb = -40 °C to +85 °C
VIH
HIGH-level input voltage VCC = 0.8 V
VCC = 0.9 V to 1.95 V
0.70×VCC
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
0.65×VCC
-
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
1.6
-
-
2.0
VIL
LOW-level input voltage VCC = 0.8 V
-
-
-
-
0.30×VCC
0.35×VCC
0.7
VCC = 0.9 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
0.9
VOH
HIGH-level output
voltage
VI = VIH or VIL
IO = -20 μA; VCC = 0.8 V to 3.6 V
IO = -1.1 mA; VCC = 1.1 V
IO = -1.7 mA; VCC = 1.4 V
IO = -1.9 mA; VCC = 1.65 V
IO = -2.3 mA; VCC = 2.3 V
IO = -3.1 mA; VCC = 2.3 V
IO = -2.7 mA; VCC = 3.0 V
IO = -4.0 mA; VCC = 3.0 V
VI = VIH or VIL
VCC - 0.1
0.7×VCC
1.03
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
1.30
1.97
1.85
2.67
2.55
VOL
LOW-level output
voltage
IO = 20 μA; VCC = 0.8 V to 3.6 V
IO = 1.1 mA; VCC = 1.1 V
IO = 1.7 mA; VCC = 1.4 V
IO = 1.9 mA; VCC = 1.65 V
IO = 2.3 mA; VCC = 2.3 V
IO = 3.1 mA; VCC = 2.3 V
IO = 2.7 mA; VCC = 3.0 V
IO = 4.0 mA; VCC = 3.0 V
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.1
0.3×VCC
0.37
V
V
V
0.35
V
0.33
V
0.45
V
0.33
V
0.45
V
II
input leakage current
± 0.5
± 0.5
μA
μA
IOFF
power-off leakage
current
ΔIOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V to 0.2 V
-
-
± 0.6
μA
ICC
supply current
VI = GND or VCC; IO = 0 A; VCC = 0.8 V to 3.6 V
-
-
-
-
0.9
50
μA
μA
ΔICC
additional supply current VI = VCC - 0.6 V; IO = 0 A; VCC = 3.3 V
Tamb = -40 °C to +125 °C
VIH HIGH-level input voltage VCC = 0.8 V
0.75×VCC
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
VCC = 0.9 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
0.70×VCC
-
1.6
-
-
2.0
VIL
LOW-level input voltage VCC = 0.8 V
-
-
-
-
0.25×VCC
0.30×VCC
0.7
VCC = 0.9 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
0.9
©
74AUP1G04
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2023. All rights reserved
Product data sheet
Rev. 12.1 — 11 July 2023
6 / 20