Absolute Maximum Ratings(Note 1)
Recommended Operating
Conditions
Supply Voltage (VCC
)
−0.5V to +7.0V
DC Input Diode Current (IIK
VI = −0.5V
)
Supply Voltage (VCC
)
4.5V to 5.5V
0V to VCC
−20 mA
+20 mA
Input Voltage (VI)
VI = VCC +0.5V
Output Voltage (VO)
0V to VCC
DC Output Diode Current (IOK
)
Operating Temperature (TA)
Minimum Input Edge Rate (∆V∆t)
VIN from 0.8V to 2.0V
−40°C to +85°C
125 mV/ns
V
V
O = −0.5V
−20 mA
+20 mA
O = VCC +0.5V
DC Output Voltage (VO)
−0.5V to VCC + 0.5V
±50 mA
VCC @ 4.5V, 5.5V
DC Output Source/Sink Current (IO)
DC VCC or Ground Current
Per Output Pin
Note 1: Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, with-
out exception, to ensure that the system design is reliable over its power
supply, temperature, and output/input loading variables. Fairchild does not
recommend operation of FACT circuits outside databook specifications.
±50 mA
−65°C to +150°C
4000V
Storage Temperature
ESD Last Passing Voltage (Min)
DC Electrical Characteristics
V
T
= +25°C
T = −40°C to +85°C
A
CC
A
Symbol
Parameter
Units
Conditions
(V)
4.5
5.5
4.5
5.5
4.5
5.5
Typ
1.5
Guaranteed Limits
V
Minimum HIGH
Input Voltage
2.0
2.0
2.0
0.8
0.8
4.4
5.4
V
= 0.1V
IH
OUT
V
V
V
1.5
2.0
0.8
0.8
4.4
5.4
or V −0.1V
CC
V
V
Maximum LOW
Input Voltage
1.5
V
= 0.1V
IL
OUT
1.5
or V −0.1V
CC
Minimum HIGH
Output Voltage
4.49
5.49
OH
I
= −50 µA
OUT
V
= V or V
IN
OH
OH
IL
IH
4.5
5.5
4.5
5.5
3.86
4.86
0.1
3.76
4.76
0.1
V
V
I
I
= −24 mA
= −24 mA (Note 2)
V
Maximum LOW
Output Voltage
0.001
0.001
OL
I
= 50 µA
OUT
0.1
0.1
V
= V or V
IN
OL
OL
IL
IH
4.5
5.5
0.36
0.36
0.44
0.44
V
I
I
= 24 mA
= 24 mA (Note 2)
I
Maximum 3-STATE
V = V , V
OZ
I
IL
IH
5.5
±0.5
±5.0
µA
Leakage Current
V
= V , GND
O
CC
I
Maximum Input Leakage Current
5.5
5.5
5.5
5.5
± 0.1
± 1.0
1.5
µA
mA
µA
V = V , GND
I CC
IN
I
Maximum I /Input
CC
0.6
V = V −2.1V
CCT
I
CC
I
Maximum Quiescent Supply Current
Minimum Dynamic
8.0
80.0
75
V
V
V
= V or GND
CC
CC
IN
I
mA
mA
= 1.65V Max
= 3.85V Min
OLD
OLD
OHD
I
Output Current (Note 2)
Quiet Output
−75
OHD
V
Figure 1, Figure 2
(Note 5)(Note 6)
Figure 1, Figure 2
(Note 5)(Note 6)
Figure 1, Figure 2
(Note 4)(Note 6)
Figure 1, Figure 2
(Note 4)(Note 6)
(Note 4)(Note 7)
(Note 4)(Note 7)
OLP
OLV
OHP
OHV
5.0
0.5
0.8
V
Maximum Dynamic V
Quiet Output
OL
V
V
V
5.0
5.0
−0.5
−0.8
V
V
Minimum Dynamic V
OL
Maximum Overshoot
V
V
+ 1.0
V
V
+ 1.5
OH
OH
Minimum V
CC
5.0
− 1.0
− 1.8
V
OH
OH
V
Droop
CC
V
V
Minimum HIGH Dynamic Input Voltage Level
Maximum LOW Dynamic Input Voltage Level
5.0
5.0
1.7
1.2
2.0
0.8
V
V
IHD
ILD
Note 2: All outputs loaded; thresholds associated with output under test.
Note 3: Maximum test duration 2.0 ms, one output loaded at a time.
Note 4: Worst case package.
Note 5: Maximum number of outputs that can switch simultaneously is n. (n-1) outputs are switched LOW and one output held LOW.
Note 6: Maximum number of outputs that can switch simultaneously is n. (n-1) outputs are switched HIGH and one output held HIGH.
Note 7: Maximum number of data inputs (n) switching (n-1) input switching 0V to 3V. Input under test switching 3V to threshold (VILD).
3
www.fairchildsemi.com