描述
High Sensitivity Duct Smoke Detector

7251DHA 数据手册

 浏览型号7251DHA的Datasheet PDF文件第2页 
7251DH  
High Sensitivity  
Duct Smoke Detector  
The System Sensor 7251DH detector is designed for  
interior duct applications where high velocity, high  
volume air changes are required for very early warning  
fire protection.  
Features  
The 7251DH high sensitivity duct smoke detector provides  
dependable performance for management of fans, blowers, and  
air conditioning systems by using an intelligent laser smoke sensor  
residing in an efficient housing design that samples air currents  
passing through a duct. The twist-in, twist-out 7251 high sensitivity  
laser smoke detector head allows easy removal for quick cleaning,  
maintenance, and replacement without removing the duct housing.  
The laser detector achieves sensitivities as low as 0.02 percent-per-  
foot by using a laser diode instead of a standard LED light source  
in the sensing chamber. Many sensitive areas cannot tolerate even  
small amounts of smoke. This 7251DH detector is designed to  
protect valuable assets and operations where systems must remain  
online at all times.  
•ꢀTemperature range 32°F to 100°F (0°C to 38°C)  
•ꢀAir velocity rating from 300 to 4,000 FPM  
•ꢀ24 VDC operation  
•ꢀEasy and quick mounting to round or rectangular ducts from  
1 ft to 12 ft (0.3 m to 3.7 m) wide  
•ꢀ3 year warranty  
Some ideal applications for the 7251DH high sensitivity duct smoke  
detector include:  
– Telecommunications switching facilities  
– Cellular telephone infrastructure  
– Integrated circuit fabrication facilities  
– Computer rooms  
– Clean rooms  
NFPA 76, Section 8.5.3.1.2.3 Very Early Warning Fire Protection, calls for  
sensors to be mounted at the return air location for a space in the  
following instances.  
(A) “Where stand-alone packed HVAC units are installed, sensors or  
ports shall be installed where return air is brought back to the unit.”  
(B)Sensors or ports shall be installed such that each covers no  
greater than 0.4 m2 (4 ft2) of the return air opening.”  
Agency Listings  
The System Sensor 7251DH high sensitivity duct smoke detector is  
designed to satisfy NFPA 76 for Very Early Warning Fire Protection.  
S911  

与7251DHA相关器件

型号 品牌 获取价格 描述 数据表
7252 GILWAY

获取价格

T-1 Subminiature Lamps
72520 MOLEX

获取价格

9.53mm (.375") Pitch Beau™ PCB Terminal Strip
72520-004H AMPHENOL

获取价格

Board Stacking Connector, 4 Contact(s), 2 Row(s), Male, Straight, Solder Terminal
72520-004HLF AMPHENOL

获取价格

Board Connector, LEAD FREE
72520-008H AMPHENOL

获取价格

Board Stacking Connector, 8 Contact(s), 2 Row(s), Male, Straight, Solder Terminal
72520-010H AMPHENOL

获取价格

Board Stacking Connector, 10 Contact(s), 2 Row(s), Male, Straight, Solder Terminal
72520-010HLF AMPHENOL

获取价格

Board Connector, LEAD FREE
72520-014H AMPHENOL

获取价格

Board Stacking Connector, 14 Contact(s), 2 Row(s), Male, Straight, Solder Terminal
72520-016H AMPHENOL

获取价格

Board Stacking Connector, 16 Contact(s), 2 Row(s), Male, Straight, Solder Terminal
72520-016HLF AMPHENOL

获取价格

Board Connector, LEAD FREE