SERIES 28
HiPer-D Accessories
Band-Master™ ATS tool and bands for termination of cable braid
600-058 tool, 600-052 and 600-090 band straps
BAND ASTER™ ATS TOOL AND BANDS
Band-
Master™ ATS 300 series SST/passivate I.A.W. AMS 2700. The Band-Master™ ATS
1
with just one band size. Approved for aerospace and defense, these straps have
successfully passed rigorous shock, vibration and environmental testing.
Band installationTool. Use with .240" (6.10 mm)
wide bands. 6.75 inches (172 mm) length, 1.2
pounds (0.6 Kg.)
Standard Band, .240" (6.10 mm) wide. Available
1
2
Figure
Description
Band installation Tool
Part Number
Pre-Coiled
Length
in.
Part Number
Flat
Accommodates Diameter
in. mm
Figure
mm
Contact Glenair or visit our website (glenair.com) to view our complete line of Band-Master™ ATS products,
including pneumatic tools for high volume production and calibration kits.
2
LENGTH ± .060 (1.5)
.240 (6.10)
.350 (8.9)
TAIL LENGTH
INDICATOR MARK
Adapter
Retention Lip
Conductors
BAND ASTER™ SHIELD TERMINATION INSTRUCTIONS
.400 (1.2mm) Min.
Length Braid Over
Termination Area
Braid
1. Prepare Cable Braid for termination process
(Figure 1).
Shield Termination
Clamping Process (Figures 4 thru 8)
2. Push Braid forward over Adapter Retention Lip
to the Adapter Incline Point (or .4" [10.2mm]
minimum braid length). Milk Braid as required
Adapter
Incline
NOTE: To free Tool Handles, move Holding Clips
to center of Tool.
2
1
4. Squeeze Gripper Release Lever and insert
Band into the front end opening of theTool.
(NOTE:Circularportionofloopedbandmust
always face downward.)
5. Aligning the Band and Tool with the Shield
Termination Area, squeeze Black Pull-Up
Handle repeatedly using short strokes until
itlocksagainstToolBody. (Thisindicatesthe
BandiscompressedtotheToolPrecalibrated
Tension.)
shield termination area (Figure 2).
3. Prepare the Band in the following manner:
IMPORTANT:DuetoConnector/Adaptercircum-
ference,itmaybenecessarytopreparetheBand
around the Cable or Retention Area.
A. Roll Band through the Buckle Slot twice.
(Bands must be double-coiled.)
Tail Length
Indicator Mark
Buckle
3
5
7
4
6
8
E
B. Pull on Band until Mark (
) is within ap-
proximately .250 inch (6.4mm) of Buckle
Slot (Figure 3). The Band may be tightened
further if desired.
NOTE: If alignment of band and shield is un-
satisfactory, tensiononbandcanberelaxed
by pushing on slotted release lever on top
of tool. Make adjustments as necessary and
again squeeze black pull-up handle.
NOTE: Prepared Band should have (
visible approximately where shown in Figure 3.
) Mark
6. Complete the Clamping Process by squeez-
7. Remove excess band from tool and dispose.
8. Inspect Shield Termination.