5ACEW_4 series
5Watt - AC-DC converter
Output specifications
Item
Operating condition
Min
Typ
Max
100
Units
%
Output voltage accuracy*
3.3V output
others
3
2
Line regulation
Load regulation
Ripple & Noise*
Full load
0.5
1
%
%
10% - 100% load
20MHz bandwidth (peak-to-peak value)
50
0.1
mV
W
Stand-by Power Consumption
Temperature Coefficient
230VAC
0.02
Over-current Protection
≥130%Io, self-recovery
3.3/5VDC output
9VDC output
12VDC output
15VDC output
24VDC output
≤7.5VDC
≤15VDC
≤16VDC
≤20VDC
≤30VDC
Over-voltage Protection
Min. load
0
%
115VAC input
230VAC input
5
50
Hold-up Time
ms
Wave-soldering
Manual-welding
260 5°C; time: 5 - 10s
360 10°C; time: 3 - 5s
Soldering Temperature
Note: *The “Tip and barrel method” is used for ripple and noise test, output
parallel 10uF electrolytic capacitor and 1uF ceramic capacitor, please refer to
AC-DC Converter Application Notes for specific information.
Approval
Model
Power
[W]
Output
[Vo]
Output
[lo]
Efficiency
[%, typ]
Capacitive load
[µF, max]
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
5ACEW_03S4
5ACEW_05S4
5ACEW_09S4
5ACEW_12S4
5ACEW_15S4
5ACEW_24S4
5
5
5
5
5
5
3.3V
5V
1515mA
1000mA
555mA
416mA
333mA
208mA
71.5
77.5
80.5
80.5
81.5
79
4000
3000
1200
1200
680
9V
12V
15V
24V
220
Note: * Use suffix ”/CM” for chassis and suffix ”/DR” for DIN-Rail mounting.
EMC specifications
CISPR32/EN55032 CLASS B
Emissions
Emissions
Immunity
Immunity
CE
EN55014-1
CISPR32/EN55032 CLASS B
EN55014-1
RE
IEC/EN 61000-4-2
EN55014-2
Contact 6KV/Air 8KV
perf. Criteria B
perf. Criteria B
ESD
RS
IEC/EN 61000-4-3
EN55014-2
10V/m
perf. Criteria A
perf. Criteria B
IEC/EN61000-4-4 2KV (See Fig.1 for typical application circuit)
IEC/EN61000-4-4 4KV (See Fig.2 for recommended circuit)
EN55014-2
perf. Criteria B
perf. Criteria B
perf. Criteria B
Immunity
Immunity
EFT
IEC/EN61000-4-5 line to line 1KV (See Fig.1 for typical application circuit)
IEC/EN61000-4-5 line to line 2KV (See Fig.2 for recommended circuit)
EN55014-2
perf. Criteria B
perf. Criteria B
perf. Criteria B
Surge
CS
IEC/EN 61000-4-6
EN55014-2
10 Vr.m.s
perf. Criteria A
perf. Criteria A
Immunity
Immunity
Voltage dip, short interruption IEC/EN 61000-4-11
and voltage variation EN55014-2
0%-70%
perf. Criteria B
perf. Criteria B
Page 2 of 5
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
5ACEW_4 – Rev. 2020-1.0
Specifications subject to change without notice.