5ACM_4 series
5W- Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
5 Watt
Wide input voltage range:
85~264VAC/100~400VDC
Over current protection
Short circuit protection (SCP)
High efficiency
Ultra-slim SIP package
Industrial grade
IEC62368/EN62368/UL62368
approval
The 5ACM_4 series is a high efficiency green power modules provided by
GAPTEC. The features of this series are: Accept either AC or DC
input, wide input voltage, high efficiency, low power consumption,
safety isolation etc. All models are particularly suitable for the appli-
cations such as industrial, electric power, instrumentation, smart home
which do not have high requirement on EMC. EMC application circuit
must be added if the products need to be applied to EMC harsh environ-
ment.
High safety isolation 4000VAC
UL-62368-1 (E347551)
Common specifications
Short circuit protection:
Temperature rise at full load:
Cooling:
Output specifications
Continuous, automatic recovery
25°C TYP
Item
Operating condition
Min Typ
Max
Units
Output voltage
accuracy
• 3.3V output
• Others
2
1
3
2
%
%
Free air convection
-25°C – +85°C
Line regulation
Load regulation
Temperature drift
Ripple & Noise*
Full load
0.5
1
%
Operation temperature range:
Storage temperature range:
Welding temperature:
10% to 100% load
100% full load
1.5
%
-40°C – +105°C
0.02
50
%/°C
mV
Wave-soldering: 260 5°C; time:5ꢀ10s
Manual-welding: 360 10°C; time:3ꢀ5s
20MHz Bandwidth
(peak-peak value)
150
0.5
Storage humidity range:
Power derating:
105% (max.)
Stand-by Power
W
-25°C ꢀ 0°C: 0.8%/°C MIN
55°C ꢀ 85°C: 1.33%/°C MIN
Over-current
Protection
≥150%Io self-recovery
Safety standard:
Safety-regulated certification:
Safety class:
IEC62368/EN62368/UL62368
EN62368/UL62368
Class II
≤ 7.5 V (Output voltage clamp)
≤ 15 V (Output voltage clamp)
≤ 20 V (Output voltage clamp)
≤ 30 V (Output voltage clamp)
Over-voltage
Protection
3.3/5V output =
9V output =
12/15V output =
24V output =
Hot plug:
Unavailable
Min. load
0
%
Case material:
Plastic [UL94-V0]
>300,000 hours
7g
Switching fre-
quency
Full load, nominal
input
60
KHz
MTBF (MIL-HDBK-217F@25°C):
Weight:
Hold-up time
• 115VAC input
• 230VAC input
15
75
ms
ms
Input specifications
Item
Test condition
Min
Typ
Max
Units
Example:
5ACM_05S4
Input voltage range • Conventional
100
85
100
240
264
400
VAC
VAC
VDC
5 = 5Watt; AC = AC-DC; M = case style; 5Vout; S = Single Output;
4 = 4kVAC isolation
• AC Input
• DC Input
Input frequency
47
63
Hz
Note:
1. Module required dispensing fixed after assembled;
2. This part is open frame, at least 6.4mm safety distance between the the
primary and secondary external components of the module is needed to
meet the safety requirement;
3. All specifications were measured at Ta = 25°C, humidity <75%, nominal input
voltage and rated output load unless otherwise specified;
4. All index testing methods in this datasheet are based on our Company’s
corporate standards;
5. The performance indexes of the product models listed in this manual are as
above, but some indexes of non-standard model products will exceed the
abovementioned requirements, and please directly contact our technician for
specific information;
6. We can provide product customization service;
7. Specifications of this product are subject to changes without prior notice.
Input current
Inrush current
Leakage current
• 115VAC
• 230VAC
0.2
0.1
A
A
• 115VAC
• 230VAC
5
A
A
10
CY0 is 1nF/400VAC
0.25
Max
mA
Isolation specifications
Item
Test condition
Min
Typ
Units
VAC
Isolation voltage
Input-Output, tested
for 1 minute
4000
Page 1 of 4
5ACM_4 – Rev. 2020-1.2
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com