54ACT11011, 74ACT11011
TRIPLE 3-INPUT POSITIVE-AND GATES
SCAS028A – D2957, JULY 1987 – REVISED APRIL 1993
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
CC
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V
+ 0.5 V
+ 0.5 V
I
CC
CC
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
IK
I
I
CC
Output clamp current, I
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
OK
O O CC
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through V
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
O
O
CC
CC
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
recommended operating conditions
54ACT11011
74ACT11011
UNIT
MIN
4.5
2
MAX
MIN
4.5
2
MAX
V
V
V
V
V
Supply voltage
5.5
5.5
V
V
CC
IH
IL
High-level input voltage
Low-level input voltage
Input voltage
0.8
0.8
V
0
0
V
V
0
0
V
V
V
I
CC
CC
Output voltage
V
O
CC
CC
I
I
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
–24
24
–24
24
mA
mA
ns/V
°C
OH
OL
t/ v
0
10
0
10
T
–55
125
– 40
85
A
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
T
A
= 25°C
54ACT11011
74ACT11011
PARAMETER
TEST CONDITIONS
V
UNIT
CC
MIN
4.4
TYP
MAX
MIN
4.4
MAX
MIN
4.4
5.4
3.8
4.8
MAX
4.5 V
5.5 V
4.5 V
5.5 V
5.5 V
5.5 V
4.5 V
5.5 V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
I
I
= – 50
A
OH
5.4
5.4
3.94
4.94
3.7
V
OH
= – 24 mA
V
OH
4.7
I
I
= – 50 mA
= – 75 mA
3.85
OH
3.85
OH
0.1
0.1
0.1
0.1
0.1
0.1
I
= 50 A
OL
OL
0.36
0.36
0.5
0.44
0.44
V
OL
I
= 24 mA
V
0.5
I
I
= 50 mA
= 75 mA
1.65
OL
1.65
± 1
40
OL
I
I
V = V
or GND
or GND,
± 0.1
± 1
A
A
I
I
CC
CC
V = V
I = 0
O
4
80
CC
I
One input at 3.4 V,
Other inputs at GND or V
5.5 V
0.9
1
1
mA
pF
I
§
CC
CC
C
V = V or GND
I CC
5 V
3.5
i
‡
§
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V
.
CC
2–2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265