Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
IEC Appliance Inlet C14 Modular Assembling Options
Standard- or Medical-Filter
5411.XX5X.XXX
Appliance inlet
Fuseholder
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
Line filter
C14
F
70° C
70° C
Description
-ꢀPanelꢀMount:
Characteristics
-ꢀModularꢀcomponentꢀselection
-ꢀIndividualꢀcomponentsꢀsolderedꢀonꢀaꢀprintedꢀcircuitꢀboard
-ꢀPlugꢀremovalꢀnecessaryꢀforꢀfuse-linkꢀreplacement
ꢀ FuseꢀdrawerꢀmeetsꢀrequirementsꢀofꢀmedicalꢀstandardꢀIEC/ENꢀ60601-1
ꢀ Theꢀfuseholderꢀisꢀaccessibleꢀfromꢀtheꢀequipmentꢀfront
-ꢀTechnicalꢀdataꢀofꢀfilter-componentsꢀseeꢀblockfilterꢀtypeꢀ5500
-ꢀFullyꢀinsulatedꢀfromꢀtheꢀrear
ꢀ Snap-inꢀversionꢀfromꢀfrontꢀsideꢀ
-ꢀ2ꢀ-ꢀ5ꢀFunctions:
ꢀ ApplianceꢀInletꢀProtectionꢀclassꢀI,ꢀConnector,ꢀLineꢀSwitchꢀ2-pole,ꢀFuse-
holderꢀforꢀfuse-linksꢀ5ꢀxꢀ20ꢀmmꢀ1-ꢀorꢀ2-pole,ꢀLineꢀfilterꢀinꢀstandardꢀandꢀ
medicalꢀversionꢀ
-ꢀSolderꢀterminalsꢀ3.5ꢀxꢀ0.8ꢀmmꢀorꢀquickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀ
mm
-ꢀQualifiedꢀforꢀuseꢀinꢀequipmentꢀaccordingꢀIEC/ENꢀ60950
Other versions on request
Approvals
-ꢀVDEꢀCertificateꢀNumber:ꢀ101307
-ꢀULꢀFileꢀNumber:ꢀE72928
-ꢀLineꢀswitchꢀwithꢀotherꢀrockerꢀmarking
References
Alternative:ꢀversionꢀwithoutꢀlineꢀfilterꢀꢀꢀFelcomꢀ64ꢀ
Weblinks
pdf,ꢀhtml,ꢀGeneralꢀProductꢀInformation,ꢀApprovals,ꢀRoHS,ꢀCHINA-RoHS,ꢀ
MatingꢀConnectors,ꢀe-Shop,ꢀSCHURTER-Stock-Check,ꢀDistributor-
Stock-Check,ꢀAccessories
Technical Data
RatingsꢀIEC
RatingsꢀUL/CSA
LeakageꢀCurrent
1ꢀ-ꢀ10ꢀAꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250ꢀVAC;ꢀ50ꢀHz
1ꢀ-ꢀ10ꢀAꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250ꢀVAC;ꢀ60ꢀHz
standardꢀ<ꢀ0.5ꢀmAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)ꢀ
medicalꢀ<ꢀ5ꢀµAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)
>ꢀ1.7ꢀkVDCꢀbetweenꢀL-Nꢀ
>ꢀ2.7ꢀkVDCꢀbetweenꢀL/N-PEꢀ
Testꢀvoltageꢀ(2ꢀsec)
-25ꢀ°Cꢀtoꢀ85ꢀ°C
25/085/21ꢀacc.ꢀtoꢀIECꢀ60068-1
fromꢀfrontꢀsideꢀIPꢀ40ꢀacc.ꢀtoꢀIECꢀ60529
Suitableꢀforꢀappliancesꢀwithꢀprotectionꢀ
classꢀ1ꢀacc.ꢀtoꢀIECꢀ61140
Solderꢀterminalsꢀ3.5ꢀxꢀ0.8ꢀmmꢀorꢀquickꢀ
connectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmm
Snap-in:ꢀ1/1.2/1.5/2/2.5/3ꢀmm1/1.2/1.5
/2/2.5/3ꢀmm
Appliance-Inlet/-Outlet
Fuseholder
C14ꢀacc.ꢀtoꢀIEC/ENꢀ60320-1,ꢀ
Fꢀacc.ꢀtoꢀIEC/ENꢀ60320-2-2,ꢀ
ULꢀ498,ꢀCSAꢀC22.2ꢀno.ꢀ42ꢀ(forꢀcoldꢀ
conditions)ꢀpin-temperatureꢀ70ꢀ°C,ꢀ10ꢀA,ꢀ
ProtectionꢀClassꢀ1
1ꢀorꢀ2ꢀpole,ꢀShocksafeꢀcategoryꢀPC2ꢀ
acc.ꢀtoꢀIECꢀ60127-6,ꢀ
forꢀfuse-linksꢀ5ꢀxꢀ20ꢀmm
DielectricꢀStrength
AllowableꢀOperationꢀTemp.
ClimaticꢀCategory
DegreeꢀofꢀProtection
ProtectionꢀClass
RatedꢀPowerꢀAcceptanceꢀ@ꢀ 5ꢀxꢀ20:ꢀ2ꢀWꢀ(1ꢀpole)/ꢀ1.6ꢀWꢀ(2-pole)ꢀperꢀ
Taꢀ23ꢀ°C
PowerꢀAcceptanceꢀ@ꢀTaꢀ>ꢀ
23°C
pole
Admissibleꢀpowerꢀacceptanceꢀatꢀhig-
herꢀambientꢀtemperatureꢀseeꢀderatingꢀ
curves
Rockerꢀswitchꢀ2-pole,ꢀnon-illuminated,ꢀ
acc.ꢀtoꢀIECꢀ61058-1ꢀ
Terminal
LineꢀSwitch
LineꢀFilter
PanelꢀThicknessꢀs
Material:ꢀHousing
Technicalꢀdetails
StandardꢀVersion,ꢀIECꢀ60939,ꢀIECꢀ
60601-1,ꢀULꢀ1283,ꢀULꢀ544,ꢀENꢀ133ꢀ
200,ꢀCSAꢀC22.2ꢀno.ꢀ8ꢀ
Thermoplastic,ꢀblack,ꢀULꢀ94V-0
Technicalꢀdetails
MTBF
>ꢀ1'400'000ꢀhꢀacc.ꢀtoꢀMIL-HB-217ꢀF
Connectors
ꢀ