Power entry modules without line filter
www.schurter.com/PG05
KEC
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole and Voltage Selector
Standard or Medical Fuse drawer
Fuse drawer must be ordered separately (see
accessories).
Fuse drawer must be ordered separately (see
accessories).
C14
70° C
Description
- Panel Mount:
Characteristics
- Available with or without internal connections
- The fuse drawer “Fingergrip” can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
- Suitable for use in equipment according to IEC/UL 60950
Screw-on version from front or rear side, snap-in version from front
side
- 3 Functions:
Appliance Inlet Protection class I, Fuseholder with interchangeable fuse
drawer for Fuse-links 5x20 mm or 6.3x32 mm 1 or 2 pole, with or
without voltage selector (step switch)
- Quick connect terminals 4.8 x 0.8 mm
Other versions on request
- Fuse drawer with other voltage values
- For protection class II
Approvals
- VDE Certificate Number: 40030345
- UL File Number: E93617
- CSA File Number: 38456
- CCC File Number: 2010010204409773
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version with line filter KFC
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Detailed request for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
13 A / 125 VAC; 60 Hz ¹
> 3 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
Appliance Inlet
Fuseholder
C14 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
10 A, Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Allowable Operation Temp.
Degree of Protection
Protection Class
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Rated Power Acceptance @
Ta 23 °C
Terminal
Panel Thickness s
Power Acceptance @ Ta >
23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Material: Housing
Voltage Selector
optional, step, 2-4 digits
1) UL/CSA: 1-pole version 13 A, 2-pole version 10 A
1
Connectors