Technical specification:
300 V
Rated voltage:
IEC 60664-1
42
Overvoltage category:
IEC 60664-1
2
Overvoltage:
IEC 60664-1
2,7 kV
A
Current rating:
0,75mm² 1,5mm²
IEC 60512-3 at 40°C
8 A
12 A
Ω
Insulation resistance:
IEC 60512
>=100 M
Pollution degree:
IEC 60664-1
3/2
Degree of protection:
IEC 60529
IP 68, in mated
condition
n
19
Temperature range:
IEC 60664-1
-30°C ... +80°C
D
Mating cycles:
IEC 60512-9a
>=100
Termination:
crimped
Materials:
Contact:
CuZn
A
Contact plating:
Contact carrier:
Coupling screw:
Moulding body:
Nickel, gold plated
TPU, UL 94
PE
2
CuZn, nickel plated
TPU, UL 94, grey
3
Contact assignment:
green-yellow
brown
PE
2
blue
3
Part no:
Description:
Length L: Cable:
41-01028
41-01029
41-01030
41-01031
41-xxxxx
41-01125
41-01126
41-01127
41-01128
41-xxxxx
SAL - 7/8 - RSW2PE - 2 / K0
SAL - 7/8 - RSW2PE - 3 / K0
SAL - 7/8 - RSW2PE - 5 / K0
SAL - 7/8 - RSW2PE - 10 / K0
SAL - 7/8 - RSW2PE - ... / K0
SAL - 7/8 - RSW2PE - 2 / K0 / 150
SAL - 7/8 - RSW2PE - 3 / K0 / 150
SAL - 7/8 - RSW2PE - 5 / K0 / 150
SAL - 7/8 - RSW2PE - 10 / K0 / 150
2m
3m
5m
10m
x
TPU, UL 20940,
black, 3x0,75mm²
Cable: 781-K07300
2m
3m
5m
10m
x
TPU, UL 20940,
black, 3x1,50mm²
Cable: 781-K08300
SAL - 7/8 - RSW2PE - ... / K0 / 150
D see data sheet cable
title:
Index: b 14.02.11 VF Ä3891
cable type changed, technical specification
changed, part no. cable in table added,
neutral line added
dim. in mm
Male connector 7/8" angled
date
name
Franz
drawn
appd.
11.10.07
11.10.07
L <= 4m: L + 40mm
tolerance of cable:
L > 4m: L + 1%
Mankopf
dwg no:
0
0,0
± 0,50mm
± 0,25mm
R
general tolerance:
41K1A312
see table
0,00 ± 0,10mm
THIS DRAWING MAY NOT BE COPIED OR REPRODUCED IN ANY WAY, AND
MAY NOT BE PASSED ON TO A THIRD PARTY WITHOUT WRITTEN PERMISSION.
OWNERSHIP AND COPYRIGHT OF CONEC GmbH
part no: