MODEL: 40DT
Digital Panel Meters 40 Series
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
THERMOCOUPLE INPUT DIGITAL PANEL METER
(4 digits, process meter)
/C02: Polyurethane coating
Functions & Features
/C03: Rubber coating
• 4 digit (±9999) panel meter
EX-FACTORY SETTING
• HOLD functions
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9535)
• High visible, 0.8" (20.3mm) high and bright LED
96 (3.78)
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
48
(1.89)
Connection: M3 screw terminals (torque 0.6 N·m)
Solderless terminal: Refer to the drawing at the end of the
section.
96 (3.78)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
mm (inch)
Applicable wire size: 0.25 to 1.65 mm
2
(AWG 22 to 16)
Screw terminal: Nickel-plated steel
MODEL: 40DT–T1–[1][2]
Housing material: Flame-resistant resin (gray)
Isolation: Input to power
Cold junction compensation: CJC sensor attached to the
input terminals
ORDERING INFORMATION
• Code number: 40DT–T1–[1][2]
Specify a code from below for each of [1] and [2].
(e.g. 40DT-T1-R/Q)
A/D conversion: Σ – Δ
Sampling rate: 10 times/sec. (100 msec.)
Averaging: None or moving average
Setting: (Front button)
• Specify the specification for option code /Q
(e.g. /C01/SET)
• Input type
• Temperature unit
INPUT
T1:
• Moving average
• Brightness
K (CA) (Usable range -150 to +1370°C, -238 to +2498°F)
J (IC) (Usable range -180 to +1000°C, -292 to +1832°F)
T (CC) (Usable range -170 to +400°C, -274 to +752°F)
R (Usable range 380 to 1760°C, 716 to 3200°F)
• Others
■Recommended solderless terminal
3.3 (.13) max
[1] POWER INPUT
AC Power
mm (inch)
K3: 100 – 120V AC
(Operational voltage range 85 - 132 V, 47 - 66 Hz)
L3: 200 – 240V AC
DISPLAY
(Operational voltage range 170 - 264 V, 47 - 66 Hz)
DC Power
Display: 4 digits of 20.3 mm (0.8 inch) height, 7-segment,
red LED
R: 24 V DC
Display range: -9999 to 9999
(Operational voltage range 24 V ±20 %, ripple 10 %p-p max.)
Minimum display/setting scale: 1°C or 1°F
Zero indication: Higher-digit zeros are suppressed.
Over-range indication:
[2] OPTIONS
blank: none
'S.ERR' blinks surpassing the permissible range.
'B.ERR' blinks at burnout.
/Q: With options (specify the specification)
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
40DT SPECIFICATIONS
ES-9535 Rev.10 Page 1/6
https://www.m-system.co.jp/