CIRCUIT PROTECTORS
Telecom Interface Protector
Lead Free
S
p
e
c
i
f
i
c
a
t
i
o
n
s
No. 385 / TIP
Packaging
000: Tape/Ammopack (1400 pcs.)
Time-Current Characteristic
Transient Tolerant (T)
Materials
Base/Cap: Brown Thermoplastic
Polyamide PA 6.6, UL 94V0
Round Pins: Copper, Sn plated
Standard
UL 248-14
CSA C22.2 No. 248.14
Operating Temperature
-40 ºC to +85 ºC (consider de-rating)
Approvals
cULus Recognized
Climatic Category
-40 ºC/+85 ºC/21 days
(EN 60068-1,-2-1,-2-2,-2-78)
Features
Surge proof for telecom applications
Reduced PCB space requirements
Highly defined cut-off times
Stock Conditions
+10 ºC to +60 ºC
relative humidity ≤ 75 % yearly average,
without dew, maximum value for 30 days-95 %
Dimensions (mm)
max.
8,5
4
Irreversible physical separation
Low internal resistance
Flame resistant encapsulated casing
CCCe for China import
Vibration Resistance
24 cycles at 15 min. each (EN 60068-6)
10 - 60 Hz at 0.75 mm amplitude
60 - 2000 Hz at 10 g acceleration
WebLinks
1,5
∅ 0,6
Further infos see:
Lead Pull Strength
10N (EN 60068-2-21)
www.wickmanngroup.com
Further application infos see
Fuseology:
www.wickmanngroup.com/download/
fuseology.pdf
Solderability
5,08
260 ºC, ≤ 3 s (Wave)
350 ºC, ≤ 3 s (Soldering iron)
Soldering Heat Resistance
260 ºC, 10 s (IEC 60068-2-20)
Holes in PCB
Marking
, TIP, T, Current Rating
Unit Weight
0.60 g (approx.)
Limits for Pre-arcing Time
Rated Current 1.0 x IN
3.0 x IN
350 mA ... 1.50 A
> 2 h
300 ms ... 5 s
Permissible continuous operating current is ≤ 70% at ambient temperature of 23ºC (73.4ºF).
Rated
Amp Voltage Breaking Cold Resistance Voltage Drop Power Dissipation Melting Integral Surge Amplitude (A)1 Approvals
Current Code Rating Capacity
0.1 x IN
1.0 x IN
1.0 x IN
10 x IN
max. (mΩ)
max. (mV)
max. (mW)
min. (A2s)
350mA 0350 125V
500mA 0500 125V
540
320
160
250
220
170
140
125
120
90
110
130
130
140
170
0.6
1.2
2.7
4.5
6.7
9.0
32
48
80
100
128
155
19
26
42
52
65
78
36
61
67
67
67
67
•
•
•
•
•
•
•
•
•
•
•
•
50 A / 125 V AC
800mA 0800 125V
50-60 Hz
1.00A 1100 125V
1.25A 1125 125V
1.50A 1150 125V
105
cos ϕ = 1.0
75
60
1
FCC 47 Part 68:
ITU-T K.20:
Minimum pulse load quantity is 2 pulses at a test generator output of 800V and 10x560µs waveform.
Minimum pulse load quantity is 30 pulses at a test generator output of 1000V, 67A and 10x700µs waveform.
Bellcore GR-1089: Minimum pulse load quantity is 50 pulses at a test generator output of 1000V and 10x1000µs.
Order
Information
Qty.
Order-
Number
Series
385
Amp Code
Packaging
Specifications are subject
to change without notice
WebSite
Europe Tel: +49 2302 662-107
Americas Tel: +1 404 699-7820
Asia Tel: +852 26 14-1108
China Tel: +86 21 6432 5146
E-mail: sales@wickmann.cn
050223
www.wickmanngroup.com E-mail: sales@wickmann.com